background image

GB

15

10. Possible causes of failure

Problem

Cause

Solution

The compressor does not start

1. No supply voltage

1. Check the supply voltage, the 

power plug and the 
socket-outlet.

2. Insufficient supply voltage

2. Make sure that the extension 

cable is not too long. Use an 
extension cable with large 
enough wires.

3. Outside temperature is too low

3. Never operate with an outside 

temperature of below +5°C.

4. Motor is overheated

4. Allow the motor to cool down. If 

necessary, remedy the cause of 
the overheating.

The compressor starts but there is
no pressure

1. Leak in the non-return valve 

1. Replace the non-return valve

2. The seals are damaged.

2. Check the seals and have any 

damaged seals replaced by a 
service center

3. The drainage screw for 

condensation water (11) leaks.

3. Tighten the screw by hand. 

Check the seal on the screw 
and replace if necessary.

The compressor starts, pressure is
shown on the pressure gauge, but
the tools do not start.

1. Loose hose connections

1. Check the compressed air hose 

and tools and replace if 
necessary.

2. Leak in a quick-lock coupling

2. Check the quick-lock coupling 

and replace if necessary.

3. Insufficient pressure set on the 

pressure regulator. 

3. Open the pressure regulator 

further.

Anleitung BT-AC 200-24 OF_SPK1:_  28.04.2008  13:23 Uhr  Seite 15

Содержание BT-AC 200-24 0F

Страница 1: ...i per l uso Compressore Brugsanvisning Kompressor Haszn lati utas t s Kompresszor B Naputak za uporabu f Kompresor 4 Uputstva za upotrebu kompresora j N vod k pou it Kompresor W N vod na obsluhu kompr...

Страница 2: ...u W Pou vajte ochranu sluchu Warnung vor elektrischer Spannung Beware of electrical voltage Attention la tension lectrique Fate attenzione alla tensione elettrica Advarsel mod elektrisk sp nding Figye...

Страница 3: ...3 1 2 9 2 4 5 3 1 7 11 10 8 7 1 6 5 3 6 8 3 3 e d a b c Anleitung BT AC 200 24 OF_SPK1 _ 28 04 2008 13 22 Uhr Seite 3...

Страница 4: ...4 4 4 Anleitung BT AC 200 24 OF_SPK1 _ 28 04 2008 13 22 Uhr Seite 4...

Страница 5: ...t oil and sharp edges 9 Look after your compressor Keep your compressor clean so that it works well and reliably Follow the maintenance instructions Check the power plug and cable regularly and have t...

Страница 6: ...r spray into the wind It is always imperative to observe the regulations of your local police authorities when spraying combustible or hazardous substances Never process media such as white petroleum...

Страница 7: ...prohibited to use the compressor in areas where work is conducted with sprayed water 6 Assembly and starting Important You must fully assemble the appliance before using it for the first time 6 1 Fitt...

Страница 8: ...has been set for the highest permitted pressure of the pressure vessel It is prohibited to adjust the safety valve or remove its seal Actuate the safety valve from time to time to ensure that it works...

Страница 9: ...no pressure 1 Leak in the non return valve 1 Replace the non return valve 2 The seals are damaged 2 Check the seals and have any damaged seals replaced by a service center 3 The drainage screw for con...

Страница 10: ...produkt j prohla uje n sleduj c shodu podle sm rnice EU a norem pro v robek A a k vetkez konformit st jelenti ki a term kek re vonatkoz EU ir nyvonalak s norm k szerint X pojasnjuje slede o skladnost...

Страница 11: ...an alternative to returning the electrical device the owner is obliged to cooperate in ensuring that the device is properly recycled if ownership is relinquished This can also be done by handing over...

Страница 12: ...the device e g sand stones or dust effects of force or external influences e g damage caused by the device being dropped and normal wear resulting from proper operation of the device The guarantee is...

Отзывы: