GB
- 20 -
11. Troubleshooting guide
Faults
Cause
Remedy
The equipment
does not start
- Power supply not connected
- Floating switch does trigger
- Check power supply
- Raise position of
fl
oating switch
The equipment
does not pump
- Intake sieve clogged
- Discharge hose kinked
- Clean intake sieve with water jet
- Unkink the hose
The equipment
does not cut out
- Floating switch cannot sink
- Place equipment correctly on shaft
bottom
Insu
ffi
cient pumping
rate
- Intake sieve clogged
- Performance reduced due to heavi-
ly contaminated and abrasive water
impurities
- Clean intake sieve
- Clean equipment and replace wear
parts
The equipment swit-
ches o
ff
after brie
fl
y
running
- Motor circuit-breaker switches the
equipment o
ff
due to excessive wa-
ter contamination
- Water temperature too high; motor
circuit-breaker switches the equip-
ment o
ff
- Unplug power plug and clean
equipment and shaft
- Ensure that maximum permissible
water temperature (35 °C) is not
exceeded
Anl_GC_DP_9035_N_SPK9.indb 20
Anl_GC_DP_9035_N_SPK9.indb 20
15.06.2018 09:29:58
15.06.2018 09:29:58
Содержание 41.707.78
Страница 4: ...4 Anl_GC_DP_9035_N_SPK9 indb 4 Anl_GC_DP_9035_N_SPK9 indb 4 15 06 2018 09 29 54 15 06 2018 09 29 54...
Страница 105: ...RUS 105 8 Anl_GC_DP_9035_N_SPK9 indb 105 Anl_GC_DP_9035_N_SPK9 indb 105 15 06 2018 09 30 11 15 06 2018 09 30 11...
Страница 111: ...RUS 111 11 35 C Anl_GC_DP_9035_N_SPK9 indb 111 Anl_GC_DP_9035_N_SPK9 indb 111 15 06 2018 09 30 12 15 06 2018 09 30 12...
Страница 142: ...GR 142 8 Anl_GC_DP_9035_N_SPK9 indb 142 Anl_GC_DP_9035_N_SPK9 indb 142 15 06 2018 09 30 16 15 06 2018 09 30 16...
Страница 147: ...GR 147 11 35 C Anl_GC_DP_9035_N_SPK9 indb 147 Anl_GC_DP_9035_N_SPK9 indb 147 15 06 2018 09 30 16 15 06 2018 09 30 16...
Страница 152: ...152 Anl_GC_DP_9035_N_SPK9 indb 152 Anl_GC_DP_9035_N_SPK9 indb 152 15 06 2018 09 30 17 15 06 2018 09 30 17...
Страница 153: ...153 Anl_GC_DP_9035_N_SPK9 indb 153 Anl_GC_DP_9035_N_SPK9 indb 153 15 06 2018 09 30 17 15 06 2018 09 30 17...
Страница 154: ...EH 06 2018 01 Anl_GC_DP_9035_N_SPK9 indb 154 Anl_GC_DP_9035_N_SPK9 indb 154 15 06 2018 09 30 17 15 06 2018 09 30 17...