32
Service & Parts Manual original Instructions
Part Number 32Z3812 US
Issue 1
TESTING
COMPONENT
S
A
A
Soak Test
15.8
Checking the oven cavity integrity.
Procedure:
Place an oven/microwave safe container with
15.8.1
approx. 2 litres of water into the oven.
Close the oven door and select ‘Soak Test’ (A)
15.8.2
from the Service mode oven tests (maximum oven
temperature, 50% microwave power, maximum fan
speed).
Run the test (30 minutes), carefully checking
15.8.3
the oven casing, joints and door seal for signs of
steam or water escaping from the oven cavity.
If necessary, rectify any leaks and repeat the
15.8.4
test.
Safely remove the container from the oven.
15.8.5
Recommission Test
15.9
The Recommission tests are performed following
the completion of a service or repair to ensure
the oven is operational before handing back to
the customer.
Some of the tests have a countdown timer where
failing to carry out a test within the time limit will
cause a test failure and the Recommission test will
have to be restarted.
Procedure:
Select ‘Recommission Test’ (A) from the
15.9.1
service mode oven tests and follow the on screen
instructions to perform the tests. Do not select the
red ‘X’unless you want to stop the test.
After a test has successfully passed, select OK
15.9.2
to continue.
When all the tests have been successfully
15.9.3
performed the display shows the Recommission test
has passed, select OK to confirm.
In the event of a Recommission test failure,
15.9.4
the detail will be recorded in the Error log. Any error
should be rectified and the Recommission test run
again.