-14-
The LAMP REPLACE indicator will light yellow when the total lamp used time (Corresponding value) reaches 3,000
hours. This is to indicate that lamp replacement is required.
The total lamp used time is calculated by using the below expression,
Total lamp used time (Corresponding value) =
t
eco
+ (
t
normal
x 1.5)
t
eco
: used time in the Eco mode
t
normal
: used time in the Normal mode and Auto mode
You can check the lamp used time following to the below procedure.
1
Press and hold the
oN/staNd-BY
button on the projector or the remote control for more than 20 seconds.
2
The projector used time and lamp used time will be displayed on the screen briefly as follows.
Counter
Projector
500H
Lamp
Lamp1
Lamp2
Normal
200H
200 H
Eco
300H
300 H
Corresponding value
600H
600 H
Total lamp used time
Projector used time
Maintenance
Lamp mode
ORDER REPLACEMENT LAMP
Replacement Lamp Type No. : POA-LMP128
Service Parts No.
: 610 341 9497
Checking the projector used time and lamp used time
Be sure to reset the Lamp counter after the lamp is replaced. When the Lamp counter is reset, the LAMP 1/2 RE-
PLACE indicator stops lighting and the Lamp replacement icon disappears.
✔
Note:
• Do not reset the Lamp counter without replacing the lamp. Be
sure to reset the Lamp counter only after replacing the lamp.
Press the MENU button to display the On-Screen Menu.
Use the Point
7 8
buttons to move the red frame point-
er to the Setting Menu icon
Use the Point
ed
buttons to move the red frame point-
er to Lamp counter and then press the
seLect
button.
A dialog box appears. Select a lamp and the “Lamp
replacement counter Reset?” appears. Select [Yes] to
continue.
1
2
Lamp counter
Select a lamp and the “Lamp replace-
ment counter Reset?” appears.
Select [Yes] again to reset
the lamp counter.
Select [Yes], then another
confirmation box appears.
Another confirmation dialog box appears and select
[Yes] to reset the Lamp counter.
3
Resetting the Lamp Counter
Auto
Normal
Eco
Содержание LC-X800
Страница 156: ...156 Parts Location Diagrams KE8 X80000 Optical Filter LC CS L21 Integrator In Assembly S06 L06 S06...
Страница 157: ...157 Parts Location Diagrams KE8 X80000 MIrror R Assembly S06 L15 Integrator Out PBS Assembly S06 L05 S06 L06...
Страница 158: ...158 Parts Location Diagrams KE8 X80000 Relay In Assembly L13 L17 L14 L18 In the Optical Lamp Unit...
Страница 159: ...159 Parts Location Diagrams KE8 X80000 L20 L07 L12 L16 L09 L15 L08 L19 L08 L12 L10 L11 In the Optical Unit...
Страница 210: ...KE8B Dec 2009 Japan 2009 Eiki Internatinal Inc A key to better communications...