Troubleshooting
error
error
code
error infomation
(See Powe Failure Detection Tree)
error
code
error infomation
(See Powe Failure Detection Tree)
Normal
0
-
Power Failure
1000
MAIN,
5V
1023
MAIN,
25V_4LCD
1001
MAIN,
-5V
1024
MAIN,
K8G
1002
MAIN,
3V
1025
MAIN,
PFC3
1003
MAIN,
S9V
1026
MAIN,
PFC4
1004
MAIN,
S16V
1027
MAIN.
DCFAN1
1005
MAIN,
16VM
1028
MAIN.
DCFAN2
1006
MAIN,
12VA
1029
MAIN.
DCFAN3
1007
MAIN,
1.8VAD
1030
ERR,
PRESSURE
1008
MAIN,
3.3VAD
1031
ERR,
FIL_DET
1009
MAIN,
1.2VFST
1032
ERR,
FIL_MTR
1010
MAIN,
PLLFST
1033
ERR,
SHUT_MTR
1011
MAIN,
1.2VPIC
1034
ERR,
EXT_FAN
1012
MAIN,
2.5VPIC
1035
SUBPOW,
12VF3
1013
MAIN,
3.3VPIC
1036
FAN,
NET_FAN
1014
MAIN,
1.8VGAM
1037
SUBPOW,
12VF2
1015
MAIN,
2.5VGAM
1038
FAN,
IN_FAN
1016
MAIN,
3.3VGAM
1039
SUBPOW,
12VF1
1017
MAIN,
15.5VGAM
1040
SUBPOW,
16VA
1018
MAIN,
K8E
1041
ERR,
IIC_DATA
1019
MAIN,
THERMO
1042
SLOT1
1020
FAN,
FN910
1043
SLOT2
1021
FAN,
FN911
1044
SLOT3
1022
FAN,
FN907
1045
SLOT4
Temperature Error
2000
Temperature Error detected on the Sensor (IC8811) (Arround the Intake Duct)
2001
Error of the detection (IC8811 communication error)
2100
Error of the detection (IC2541 communication error)
2200
Temperature Error detected on the Sensor (IC8811) and Thermister (TH901)
Lamp Error
3000
Lamp1 fails on
3001
Lamp1 goes out
3002
Communication Error on Lamp1
3100
Lamp2 fails on
3101
Lamp2 goes out
3102
Communication Error on Lamp2
System Error
4000
FPGA IO, NIOS Config Error
4001
FPGA MOTHER Config Error
4002
FPGA SW, FINE Config Error
4003
PW DPORT OUT Error
Error History Log
This projector provides the error history log function. To
check the logs, you need to enter the service mode and se-
lect Group No. "
91
" and Item No. "
0
" to "
49
". The error code
is displayed on the Data column. The description of the error
code is listed on the table below.
* How to enter the service mode and select the group, item
and data value, see "Service Adjustment Menu Opera-
tion".
Group
No.
Item
No.
Data
(Error Code)
91
0
1
2
3
:
:
49
✻
<- Latest Error
✻
✻
✻
:
:
✻
How to reset the error History Log
1. Enter the Service Mode, and select Group No. "
91
" and Item No. "
50
".
2 The history log will be reset when the Data Value is set to "
10
". The value automatically returns to "0".
* How to enter the service mode and select the group, item and data value, see "Service Adjustment Menu Operation".
Содержание LC-X800
Страница 156: ...156 Parts Location Diagrams KE8 X80000 Optical Filter LC CS L21 Integrator In Assembly S06 L06 S06...
Страница 157: ...157 Parts Location Diagrams KE8 X80000 MIrror R Assembly S06 L15 Integrator Out PBS Assembly S06 L05 S06 L06...
Страница 158: ...158 Parts Location Diagrams KE8 X80000 Relay In Assembly L13 L17 L14 L18 In the Optical Lamp Unit...
Страница 159: ...159 Parts Location Diagrams KE8 X80000 L20 L07 L12 L16 L09 L15 L08 L19 L08 L12 L10 L11 In the Optical Unit...
Страница 210: ...KE8B Dec 2009 Japan 2009 Eiki Internatinal Inc A key to better communications...