4-9
EK-815U
2. ABC Calibration
Note: (1)After replacing optical engine module or main
board, please execute the ABC calibration.
Inspection item:
-
Check if can do the ABC calibration
successfully.
Criteria - It appears “Success”after do ABC
calibration.
Procedure - Enter into service mode.
- Select “Light Sensor Calibration”
-
Press "Enter"
- At last it will display "done" or
"unsuccessful", "done" means calibration
pass ,"unsucessful" means calibration
NG.