Eicon Networks Eiconcard C90 Скачать руководство пользователя страница 2

www.eicon.com

Fourth Edition (June 2003)

203-227-04

Eicon, Eiconcard, and the Eicon logo are either trademarks or registered 
trademarks of Eicon Networks Corporation.

Changes are periodically made to the information herein; these changes will be 
incorporated into new editions of the publication. Eicon Networks may make 
improvements and/or changes in the products and/or programs described in 
this publication at any time.

Copyright © 1996-2003 Eicon Networks Corporation. All rights reserved, 
including those to reproduce this publication or parts thereof in any form without 
permission in writing from Eicon Networks Corporation.

Содержание Eiconcard C90

Страница 1: ...www eicon com Eiconcard Family Installation Guide for PCI Compatible Bus...

Страница 2: ...herein these changes will be incorporated into new editions of the publication Eicon Networks may make improvements and or changes in the products and or programs described in this publication at any...

Страница 3: ...ction 10 VHSI cables 10 Making a V 24 Connection 11 V 24 cables 11 Status lights Eiconcard C90 C91 S T and C91 V2 12 Status Lights Eiconcard S91 S T and S91 V2 13 Status Lights Eiconcard S90 S94 and S...

Страница 4: ...umption 32 Technical specifications Eiconcard S series 33 Technical data 33 Hardware installation 33 External interface 33 Performance 33 Power requirements 34 Environmental requirements 34 VHSI ports...

Страница 5: ...otocols such as X 25 Frame Relay PPP SDLC and HDLC over leased lines dial up lines or ISDN lines V 24 port The V 24 port supports line speeds of 64 kbps ISDN BRI port The ISDN BRI port supports transf...

Страница 6: ...duplex communications over a V 24 V 35 EIA 530 V 36 RS 449 or X 21 interface at speeds of up to 2 Mbps per port depending on the interface ISDN BRI port The ISDN BRI port supports transfer rates of u...

Страница 7: ...on page 31 for more information on the PCI capability of your card c Insert the Eiconcard into the slot and fasten it with a screw 3 Test the Eiconcard The application software purchased with the Eic...

Страница 8: ...dwide In Europe and most countries outside of North America and Japan the NT1 is installed at the central switching office by the ISDN provider In these areas the Eiconcard can be connected directly t...

Страница 9: ...Note Some NT1s do not support connections over 75 meters If the connection spans less than 75 meters 250 feet set the NT1 to 50 ohms of resistance and do not connect the terminating resistor Consult t...

Страница 10: ...e Eiconcard recognizes the cable and automatically prepares the port for that interface Consult the documentation which came with your networking software for more information about port configuration...

Страница 11: ...e with your networking software for more information about port configuration V 24 cables The following table lists the most common connections supported by the V 24 port and specifies the part number...

Страница 12: ...ISDN line is active and operating normally ISDN B channel Status Eiconcard C91 S T and C91 V2 only The B channels are used for the link to the remote ISDN device Off There is no connection Blinking A...

Страница 13: ...N line is active and operating normally ISDN B channel status The B channels are used for the link to the remote ISDN device Off There is no connection Blinking Attempting to connect to the remote dev...

Страница 14: ...S94 66 MHz Configuration status This status light illuminates when the Eiconcard and or port is being configured Consult the documentation provided with the configuration software for information abou...

Страница 15: ...cal and signaling EIA RS 232 C Electrical and signaling ISO 2110 Connector type for the DCE side of a V 24 VHSI Modem Cable V 35 CCITT V 28 Some signals for electrical CCITT V 35 Some signals for elec...

Страница 16: ...onnected to the connector case and shell at each end of the cable The braid must be connected through its full circumference Wires identified as twisted pairs must be paired If you do not wire twisted...

Страница 17: ...S Request to Send Output 105 5 CTS Clear to Send Input 106 6 DSR Data Set Ready Input 107 7 SGND Signal Ground Common 102 8 DCD Data Carrier Detect Input 109 15 TCLK Transmit Clock DCE Input 114 17 RC...

Страница 18: ...a VHSI V 24 DCE cable For additional information required to construct your own cables see Cable construction information on page 16 Figure 2 VHSI V 24 DCE connections 7 VHSI V 24 DRAIN WIRE 1 BRAID...

Страница 19: ...n 101 2 TXD Transmit Data Output 103 3 RXD Receive Data Input 104 4 RTS Request to Send Output 105 5 RTS Clear to Send Input 106 6 DSR Data Set Ready Input 107 7 SGND Signal Ground Common 102 8 DCD Da...

Страница 20: ...ections required to construct a VHSI V 24 DTE cable For additional information required to construct your own cables see Cable construction information on page 16 Figure 4 VHSI V 24 DTE connections VH...

Страница 21: ...erminal Ready Output 108 J RI Ring Indicator Input 125 L TEST Local Loopback Activation Output 141 N RLB Remote Loopback Output 140 P TXD Transmit Data Output 103A R RXD Receive Data Input 104A S TXD...

Страница 22: ...a VHSI V 35 cable For additional information required to construct your own cables see Cable construction information on page 16 Figure 6 VHSI V 35 connections VHSI V 35 DRAIN WIRE 5 23 6 24 10 28 8...

Страница 23: ...Data Carrier Detect Input 109B CF B 11 CLK Transmit Clock DTE Output 113B DA B 12 TRXC Transmit Clock DCE Input 114B DB B 13 CTS Clear to Send Output 106B CB B 14 TXD Transmit Data Output 103B BA B 15...

Страница 24: ...cable For additional information required to construct your own cables see Cable construction information on page 16 Figure 8 VHSI EIA 530 connections VHSI EIA 530 DRAIN WIRE 4 22 5 23 6 24 7 25 8 17...

Страница 25: ...7A 12 DTR Data Terminal Ready Output 108A 13 DCD Data Carrier Detect Input 109A 14 RLB Remote Loopback Output 140A 15 RI Ring Indicator Input 125A 17 CLK Transmit Clock DTE Output 113A 18 TI Test Indi...

Страница 26: ...r additional information required to construct your own cables see Cable construction information on page 16 Figure 10 VHSI V 36 RS 449 connections VHSI V 36 RS 449 DRAIN WIRE 4 22 5 23 6 24 7 25 8 8...

Страница 27: ...103A 3 C A Control Signal Output 105A 4 R A Receive Data Input 104A 5 I A Indication Input 109A 6 S A Signal Element Timing Input 115A 7 B A Byte Timing Input 114A 8 SGND Signal Ground Common 102 9 T...

Страница 28: ...uired to construct a VHSI X 21 cable For additional information required to construct your own cables see Cable construction information on page 16 Figure 12 VHSI X 21 Connections VHSI X 21 1 19 4 22...

Страница 29: ...perations are conducted through the V 36 interface For additional information required to construct your own cables see Cable construction information on page 16 Figure 13 VHSI VHSI connections VHSI V...

Страница 30: ...4 RTS Request to Send Output 105 5 CTS Clear to Send Input 106 6 DSR Data Set Ready Input 107 7 SGND Signal Ground Common 102 8 DCD Data Carrier Detect Input 109 15 TCLK Transmit Clock DCE Input 114 1...

Страница 31: ...perating pressure 86 to 106 kPascals Maximum tolerance in power supply variation 5 to 5 Model CPU Memory Flash V 24 Ports ISDN BRI Ports Connector Key PCI Bus up to Eiconcard C90 16 MHz Motorola 68302...

Страница 32: ...l clocking DTE or DCE or split transmit internal receive external Power Consumption Warning Check that power supply will not be overloaded Maximum power consumption of the board is stated above The us...

Страница 33: ...Flash 1 N A 5V 2 1 32 bits 33 MHz Eiconcard S91 S T 25 MHz Motorola 68302 1 MB RAM 1 MB Flash 1 1 5V 2 1 32 bits 33 MHz Eiconcard S91 V2 50 MHz Motorola 855T 8MB SDRAM 1 1 3 3V or 5V 2 2 32 bits 66 M...

Страница 34: ...21 with V 11 X 27 signaling Internal or external clocking DTE or DCE or split transmit internal receive external Power consumption Warning Check that power supply will not be overloaded Maximum power...

Страница 35: ...ested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a...

Страница 36: ...XX The digits represented by are the REN without a decimal point e g 03 is a REN of 0 3 For earlier products the REN is separately shown on the label If this equipment causes harm to the telephone net...

Страница 37: ...mpliance with the above conditions may not prevent degradation of service in some situations Warning For your safety follow these steps before you remove the cover from your computer 1 Turn off the po...

Страница 38: ...s Corporation d clare que cet quipement r pond aux exigences essentielles et autres dispositions pertinentes de la directive 1999 5 EC GR Eicon Networks Corporation fl fl fi fi 1999 5 EC IC Eicon Netw...

Страница 39: ...talling other adapters into the host equipment The equipment must be installed such that with the exception of the connections to the host clearance and creepage distances shown in the table below are...

Страница 40: ...ate of the computer This ensures proper grounding which is necessary for safety purposes This customer equipment may only be installed in host equipment where there is at least 2 mm of air gap between...

Отзывы: