14
EA
Communication error
Check cabling between touch control
and power board
Replace touch control
Replace power board
U400
Overvoltage due to wrong connection
Turn off power supply voltage and
connect cooktop properly
COOKING ZONE SPECIFIC ERRORS
Error code
Description
Remedy
E2
Over temperature of cooking zone
Allow cooking zone to cool down
E3
Inapplicable pot
Use suitable pot
E4
Cooking zone does not exist,
configuration data is incompatible
Download correct configuration
E5, E6
Error on filter board/generator
Replace filter board/generator
E7
Unknown failure (master is not able
to assign the failure code)
Contact technical support
E8
Fan defective
Replace fan
E9
Temperature sensor defective
Replace temperature sensor