Initialisation Time
: 70 seconds. On power up red and amber lights flash momentarily to show
they are operational.
Operating Temperature
: -10°C to 40°C
Humidity Range
: 15% to 95% R.H. (non-condensing)
Radio Frequency
: 868 MHz band
RF Power
: +5dBm
Range
: 100 meters (minimum) in free space (without use of the “Repeater” function)
Entering House Code Mode:
Pressing and holding the House Code switch until the red light illuminates,
then releasing puts the
RadioLINK
CO Alarm into House Code mode.
House Code Mode:
The
RadioLINK
CO Alarm transmits and receives specific codes. The red light will
flash every 5 or 10 seconds (depending on number of units coded - up to 12 units, the flashes are every
5 seconds, above 12 units the flashes are every 10 seconds) to indicate the number of House Coded
units in the system.
Duration of House Code Mode:
Exits mode automatically after 30 minutes (Alternatively manually exit
by pressing the house code button; this sends a
RadioLINK
“exit house code” signal to all other
RadioLINK
devices which can act on it.
Clearing House Codes:
The House Codes memorised can be deleted (i.e. the Ei262 can be uncoded)
by pressing and holding the House Code switch on for about 6 seconds. The
RadioLINK
red Indicator
light comes on solidly, then flashes rapidly (alternating with the green light if on mains power) and stops.
Release the House Code switch. The Ei262 has now been returned to the default factory setting.