If you installed Smoke Alarms with Ra modules and did not House Code
them, you may be receiving alarm signals from a neighbouring system. This can
be easy rectified by “House Coding” your Alarms - see the ‘Ra Module
Booklet’.
1. To cancel a false alarm from a Smoke Alarm (which has its red light flashing
rapidly), press the Test/Hush button (the Smoke Alarm will automatically switch to
a reduced sensitivity condition).
The Smoke Alarms will be silenced for a period of approximately 10 minutes. The
red light on the cover of the Smoke Alarm will flash every 10 seconds (instead of
40 seconds) to indicate that the unit has been silenced.
2. The Smoke Alarm will reset to normal sensitivity at the end of the silenced period
(10 minutes). If additional silenced time is required, simply push the Test/Hush
button again.
3. If kitchen usage/layout is such that there are an unacceptable level of nuisance
alarms, re-locate the Smoke Alarm further away where it will be less affected by
cooking fumes etc. We recommend the use of a Heat Alarm in the Kitchen area to
avoid such nuisance alarms.
5.3 Power Supply Monitoring
5.3.1 What to do when an Alarm is beeping/flashing:
a)
If a Smoke Alarm is beeping about every 32 seconds with the yellow light flashing
at the same time:
- This indicates that the Lithium Battery is partially depleted and the Smoke Alarm
needs to be replaced. (check the “replace by” date marked on the side of the
Alarm).
20
Содержание EIB650i Series
Страница 2: ......
Страница 6: ...Quick Start Guide TEST ALARM TEST ALARM AT LEAST WEEKLY PRESS THE TEST BUTTON 5...