(Note: The Ra module can be returned to the originally factory settings by
pressing and holding the House Code switch until the blue light flashes and then releasing.
This will take about 7 seconds. This clears the House Codes that have been learnt).
Supply Voltage:
3V internal lithium battery (non-replaceable)
RF Range:
A minimum of 100 metres in free space
RF Visual Indicator:
Blue light flashes continuously for 0.5 to 3.5 seconds while
transmitting RF signal
RF Frequency:
926MHz (1% duty cycle)
Dimensions:
57mm length x 30mm depth x 18mm height
Temperature Range:
0° to 40°C
Humidity Range:
15% to 95% Relative Humidity (non-condensing)
Interconnect *:
Up to 12 Ra or RadioLINK modules
Optional Accessories:
- EIB407RF Manual Call Point
- EIB428RF Relay Module
- EIB450 RadioLINK Alarm Controller
Approvals:
ACMA compliance to AS/NZS 4268:2012
EMC performance to EN 301 489-1 in accordance
with EN 301 489-3
*
We recommend, for ease of installation and RF communication, that up to 12 RF devices can be installed in
any one RF coded system. Please contact us for further advise if additional RF devices are required.
16
Technical Specifications