background image

Introduction

Congratulations on purchasing an Ei600 Series RF RadioLINK module. These RF
modules can be easily installed in the Ei600 Series Alarm to provide you with an RF
interconnected fire warning system – when one Alarm senses fire and sounds a
warning, all the other Alarms will also sound a warning. This helps to ensure the
alarm sound will be heard throughout the property.

Installation

1.

The Ei600 Series Alarm must be installed as per the guidance in the instruction

booklet ‘

Battery Powered Smoke & Heat Alarms

’.

2.

Remove the RF module from the packaging and using the pull tag, carefully

insert into the back of the Alarm (see figure 1) - (some Alarm models may have the
RF Module already fitted).

3.

Ensure that the battery is connected in the 9V Replaceable Battery Models.

House code the Alarms as follows:

4.

Before fitting the Alarm to the mounting plate, press and hold the ‘House Code’

switch on the rear of the RadioLINK module until the red light comes on (see
Figures 2a) and then release.

5.

Twist the Alarm onto its mounting plate.

6.

Similarly press and hold the House Code switch on the second Alarm until its red

light comes on and then release. Twist the Alarm onto its mounting plate. Put all the
remaining alarms into House Code mode similarly and attach to the mounting plate
in the same manner in less than 15 minutes. (They automatically exit house code
mode after 30 minutes).

2

B16971-R0-Ei600 RF-U&C  28/6/10  12:13 PM  Page 2

Содержание Ei605MRF

Страница 1: ...your Smoke Alarm The leaflet should be regarded as part of the product If you are just installing the unit the leaftet must be given to the householder The leaflet is to be given to any subsequent us...

Страница 2: ...f the Alarm see figure 1 some Alarm models may have the RF Module already fitted 3 Ensure that the battery is connected in the 9V Replaceable Battery Models House code the Alarms as follows 4 Before f...

Страница 3: ...lue light flashes every 5 seconds with 4 Alarms in your system you should see 4 blue light flashes and so on with the 10th unit the blue flash is longer to help with the counting Check that the number...

Страница 4: ...arm on the mounting plate The blue light will no longer be flashing Note As this Alarm exits house code mode it sends a radio message to all the other Alarms to exit the house code mode Check that all...

Страница 5: ...e RadioLINK signals between the Alarms Accordingly one or more Smoke Heat Alarms may have difficulties in communicating to all the other Alarms in the system If when checking the RadioLINK interconnec...

Страница 6: ...e 4 iii rotate re locate the units e g move them away from metal surfaces or wiring After making these changes to the RF signal path the RadioLINK signals may still not be reaching all the Alarms in y...

Страница 7: ...of the Alarms senses fire and sounds a warning all the other Alarms will also sound a warning This helps to ensure the alarm will be heard throughout the property As a safety feature the Alarms as sup...

Страница 8: ...e flashing stops Manually Testing your Alarms It is recommended that you test your Alarms after installation and then at least weekly to ensure the units are working It will also help you and your fam...

Страница 9: ...io paths have not been disrupted by moving furniture or renovations and if so to give a warning of these and other faults Getting Your Alarm Serviced If your Alarm fails to work after you have read th...

Страница 10: ...retion repair or replace the faulty unit Do not interfere with the Alarm or attempt to tamper with it This will invalidate the guarantee but more importantly may expose the user to shock or fire hazar...

Страница 11: ...11 B16971 R0 Ei600 RF U C 28 6 10 12 13 PM Page 11...

Страница 12: ...bury Rd Oswestry Shropshire SY10 8NN U K Tel 0870 758 4000 www aico co uk Ei Electronics Shannon Co Clare Ireland Tel 061 471277 www eielectronics com P N B16971 Rev 0 Ei Electronics 2010 B16971 R0 Ei...

Отзывы: