Страница 1: ... vital information on the operation and installation of your Smoke Alarm The leaflet should be regarded as part of the product If you are just installing the unit the leaftet must be given to the householder The leaflet is to be given to any subsequent user Model Ei450 Alarm Controller Fire and CO ...
Страница 2: ...ion 3 House Coding 4 Operation 5 System Diagnostics 6 Five Year Guarantee 7 Troubleshooting the RF link 8 Limitations of Radio Communications 9 Technical Specification 10 Getting your Ei450 Serviced 3 6 8 13 17 21 22 23 24 25 Page 2 ...
Страница 3: ... ID function Check this page on our website for a complete and accurate list of products that support this function Remote Locate This will silence all the Alarms in the system except the one sensing Fire or CO Remote Silence This will silence all the Alarms in the system Fire Indicator Indicates a that a Fire Alarm has been activated CO Indicator Indicates a that a CO Alarm has been activated EOL...
Страница 4: ...Fire CO Alarm Controller Fire Indicator Low Battery Indicator CO Indicator Light Segments 4 Segment Colour Activity Function enabled Test Control Button RF signal activity Function complete 4 ...
Страница 5: ...gy Ei160RC Ei2110 Series Smoke Alarms For most up to date works with list check webpage www eielectronics com articles ei450 memory id products html The Alarms must be fitted on Ei168RC RadioLINK bases Ei605 Ei650 Series Smoke Alarms The Alarms must be fitted with the appropriate Ei605 series RadioLINK module Ei208 Battery Powered Carbon Monoxide Alarms The Alarms must be fitted with Ei200MRF Radi...
Страница 6: ...evel If it intended for a disabled person to operate the controller an alternative mounting location should be considered Also consider security and chose a location where it will not be accidently or otherwise operated Turn on the system by sliding the switch to the on position 6 MODE POWER H CODE OFF ON ...
Страница 7: ...trol switches etc in the system must be put into house code For instructions on how to house code the Ei450 controller see the House Code section of this manual For instructions on house coding the other devices please refer to their individual manuals Repeat this procedure for all Alarms and RadioLINK devices in the system Fire CO Alarm Controller Fire CO Alarm Controller Fire CO Alarm Controller...
Страница 8: ...y also result in a system malfunction Press and hold the House Code switch on the back of the controller until all segments light up blue then release The segments will flash rapidly for a moment on entering house code H CODE House code all other RadioLINK Alarms and accessories in the system Consult the instruction manuals on how to house code these devices 51 1 8 Fire CO Alarm Controller MODE PO...
Страница 9: ...r remains in house code If it fails to flash the correct number of times then consult the TroubleshootingtheRFlink sectionofthisinstructionmanual Now walk around the house to verify that all the other RadioLINK Alarms and RadioLINK devices are giving the correct amount of flashes If any of these fail to flash the correct number of times then consult the Troubleshooting the RF link section of this ...
Страница 10: ...hen send a Cancel signal to all the other RadioLINK devices to exit House code After a short period the blue light will turn off and the system will return to standby mode normal Depending on the number of Alarms and RadioLINK devices in the system this period could vary from 5 to 20 Seconds If you choose to make the switch tamper proof remove the pip plastic post using a pliers or similar tool R ...
Страница 11: ...button on the Ei450 i controller until the TEST segment lights blue This indicates a RadioLINK test signal has been activated All the Alarms in the system will sound for a short period and then stop If the test fails go to Troubleshooting the RF link section 11 Fire CO Alarm Controller Fire CO Alarm Controller ...
Страница 12: ...controller press and hold the house code switch All segments will flash blue briefly and then go solid After 5 seconds approx the segments will start flashing blue At this point release the house code switch The Ei450 has now been reset To reset the other Alarms and accessories in the system consult the appropriate instruction manuals Fire CO Alarm Controller MODE POWER H CODE OFF ON 12 ...
Страница 13: ...y of the systems elements or household electrical works Press the button on the Ei450 i controller until the TEST segment lights up blue Release the button All Alarms in the system will sound for a short period and then stop If the MEMORY segment lights up blue instead of the TEST it means that a CO or Fire alarm was previously activated See the fire and CO memory sections and report the incident ...
Страница 14: ...GRZV ZKLOH HYDFXDWLQJ WKH premises Telephone the appropriate authorities to report the incident If the fire indicator is lighting and there is no obvious fire press the button The LOCATE segment will change from red to blue After a 10 to 40 seconds period all the Alarms in the system will stop sounding except the source Alarm s KHQ WKH DODUP V VWHP VRXQGV RFDWH WKH VRXUFH ODUP V Fire CO Alarm Cont...
Страница 15: ...larm that has previously been activated e g one that false alarmed when the house was not occupied 1 After the Alarm deactivates the Fire indicator will flash alternatively with the MEMORY segment red for 2 minutes and then stop 2 To recall the memory press the button the MEMORY segment will light blue and the source alarm will sound briefly and stop several times 3 To reactivate the memory featur...
Страница 16: ...2 To recall the memory press the button the MEMORY segment will light blue and the source alarm will sound briefly and stop Depending on the number of alarms in the system the source alarm will sound and stop a number of times 3 To reactivate the memory feature press and hold the button briefly while the CO Icon is still flashing This reactivation can be repeated indefinitely as long as the icon i...
Страница 17: ...n test only works with some RadioLINK Alarms To check the current list of Alarms supported or for additional maintenance and diagnostic information please go to this webpage ZZZ HLHOHFWURQLFV FRP DUWLFOHV HL PHPRU LG SURGXFWV KWPO Alternatively use your smart phone to capture this QR code and download the page immediately Remove the Ei450 controller from its cradle If the unit has been tamper proo...
Страница 18: ...the walk round test described previously 2 Identify any Alarm that been previously activated The procedure is used to manually exit the diagnostic If there has been 2 minutes of inactivity the alarm controller will automatically exit the diagnostic mode To enter the system diagnostic mode use a small screwdriver to press and release the MODE button on the back of the unit All segments will flash g...
Страница 19: ...ndividual Alarm is sounding The test will automatically cease after 2 minutes or if the button is pressed again If an alarm memory has been set the TEST and MEMORY segments will flash green alternatively after entering the system diagnostics mode While the MEMORY segment is illuminated press the button until the MEMORY segment goes blue 7ZR PLQXWH RQJ 7HVW ODUP GHQWLILFDWLRQ 7HVW 19 Fire CO Alarm ...
Страница 20: ...tification test after 2 minutes or if the system diagnostic button is pressed again Press and hold the MODE switch on the back of the unit The green segments will light up When these segments start flashing release the button The memory identification is now cleared To erase the alarm identification memory press and hold the MODE button on the back of the alarm for about 6 seconds until all the se...
Страница 21: ...rised dismantling or contamination howsoever caused This guarantee excludes incidental and consequential damage This guarantee does not cover costs associated with the removal and or installation of units If the product should become defective within the guarantee period it may be returned with proof of purchase carefully packaged and with the problem clearly stated to the place of purchase or pho...
Страница 22: ...on 6 on Limitations of Radio Frequency Signals Try rotating the units or relocating the units e g move them away from metal surfaces or wiring as this can significantly improve signal reception Rotating and or relocating the units may move them out of the range of existing units even though they may have already been House Coded correctly in the system It is therefore important to check that all A...
Страница 23: ...an be rectified see Section 5 ii Receivers may be blocked by radio signals occurring on or near their operating frequencies regardless of the House Coding The Ei450 i controller has been tested to EN 300 220 1 V1 3 1 2000 09 in accordance with the requirements of EN 300 220V1 1 1 2000 09 These tests are designed to provide reasonable protection against harmful interference in residential installat...
Страница 24: ...on technician 7HFKQLFDO 6SHFLILFDWLRQ Supply Voltage Powered for life Lithium battery DWWHU DSDFLW P K RF Frequency 868 499Mhz Temp Range 0oC to 40oC Cat 3 Humidity 15 95 Non Condensing Receiver Category Cat 2 RF Performance EN 300 220 EMC Performance EN 301 489 5 3RZHU G P Range 150 meters in free space Number of RF interconnected Alarms 12 per house code group Note For applications with greater ...
Страница 25: ... nearest address given at the end of this leaflet If it needs to be returned for repair or replacement slide the switch to the off position place it in a padded box and send it to Customer Assistance and Information at the nearest address given on the unit or in this leaflet State the nature of the fault where the controller was purchased and the date of purchase 25 MODE POWER H CODE OFF ON ...
Страница 26: ...sal will prevent possible harm to the environment or to human health When disposing of this product please separate it from other waste streams to ensure that it can be recycled in an environmentally sound manner For more details on collection and proper disposal please contact your local government office or the retailer where you purchased this product 0889 26 ...
Страница 27: ...27 ...
Страница 28: ...UN Maesbury Road Oswestry Shropshire SY10 8NN U K Telephone 0870 7584000 ZZZ DLFR FR XN L OHFWURQLFV Shannon Industrial Estate Shannon Co Clare Ireland Telephone 353 0 61 471277 ZZZ HLHOHFWURQLFV FRP 3 1 5HY Ei Electronics 2012 ...