4. When the FIRE icon stops flashing, the memory recall is complete, the Alarm will stop sounding and
the Alarm controller will return to standby with all segments extinguished.
5. The memory is now erased and pressing the button again will perform a normal test.
The CO memory feature enables the identification of a CO Alarm
that has previously been activated, e.g. a CO incident while the
house was not occupied.
1. After the Alarm deactivates, the CO indicator will flash alternatively
with the MEMORY segment (red) for 2 minutes and then stop. For
the next 24h hours they will flash alternatively once a minute.
2. To recall the memory press the button, the MEMORY segment
will light blue and the source alarm will sound briefly and stop.
Depending on the number of alarms in the system the source alarm will sound and stop a number of times.
3. To reactivate the memory feature press and hold the button briefly while the CO Icon is still flashing.
This reactivation can be repeated indefinitely as long as the icon is still flashing. If the button is not
pressed the memory recall will timeout in 10 seconds.
4. When CO icon stops flashing, the memory recall is complete, the Alarm will stop sounding and the
Alarm controller will return to standby with all segments extinguished.
5. The memory is now erased and pressing the button again will perform a normal test.
16
&20HPRU\
Fire / CO Alarm Controller
Fire / CO Alarm Controller