Monitoring
The Ei207 / 208 series CO alarm will self check (monitor) itself and give a status update
every minute (approx) if there are any problems.
The status of the alarm can also be checked on demand by using the test button. The
table below shows the status response to both the self check and on demand testing.
If the alarms are indicating a fault, pressing the test button will silence the beeps for a
24 hour period. This is for your conveinence and can only be done once.
Maintenance
Clean the outside case by occasionally wiping with a clean damp cloth. Do not use any
cleaning agents, bleaches, detergents or polishes, including those in aerosol cans. Avoid
spraying air fresheners, hair spray, paint or other aerosols near the CO Alarm. Do not
place air fresheners near the unit.
Standby
No visual or audible indication if unit is OK
Status Result
Unit OK ( Button Test)
Off
Off
On
On
Low Battery
Off
1 Flash
1 Beep
See Note
Off
Sensor Fault
Off
2 Flashes
2 Beeps
Replace Unit
Off
Monitoring Summary
Red LED
(Alarm)
(Fault)
(Power)
Amber LED
Green LED
Sounder
LCD Display
Action
End of Life (EOL)
Off
3 Flashes
3 Beeps
Replace Unit
Off
Note
*
- For model Ei207 alarms replace the batteries - For model Ei208 alarms check the replace by date on the side of the alarm
17