Ei Electronics Ei 3105TY Скачать руководство пользователя страница 15

Smoke Alarm Ei 100TYC with built-in Lithium battery. For 

dual

protection install each type.

The Home Office states (in FB2):

“If your home has more than one floor, at least one alarm
should be fitted on each level. In this case a combination of
Optical and Ionisation alarms, preferably interconnected, will
give the best protection.

GETTING YOUR SMOKE ALARM SERVICED

If your Smoke Alarm fails to work after you have read the
sections on “Connecting the battery” and “Looking after your
Smoke Alarm” contact Customer Assistance at the nearest
address given at the end of this leaflet. If it needs to be
returned for repair or replacement put it in a padded box (with
the end of life wire cut) and send it to “Customer Assistance
and Information” at the nearest address given on the Smoke
Alarm or in this leaflet. State the nature of the fault, where the
Smoke Alarm was purchased and the date of purchase.

FIVE YEAR  GUARANTEE  (Limited)

Ei Electronics guarantees this product against any defects
that are due to faulty material or workmanship for a five year
period after the original date of consumer purchase or receipt
as a gift. This guarantee only applies to normal conditions of
use and service, and does not include damage resulting from
accident, neglect, misuse unauthorised dismantling or
contamination howsoever caused. If this product has become
defective it must be returned to Ei Electronics (see “Getting
Your Smoke Alarm Serviced”) with proof of purchase. If the
product has become defective during the five year guarantee
the manufacturer will repair or replace the unit without charge.
This guarantee excludes incidental and consequential
damages.

Do not interfere with the product or attempt to tamper with it.
This will invalidate the guarantee.

15

Ion Sensor

Best for fast flaming fires

- small smoke particles

Optical Sensor

Best for slow smouldering fires

- large smoke particles

B14355-R4-TY-UC-ENG-3105  21/12/10  1:30 PM  Page 15

Содержание Ei 3105TY

Страница 1: ...with a plastic bag or similar before renovations begin Ei Electronics 2008 P N B14355 Rev4 10 YEAR SMOKE ALARM WITH 10 YEAR LITHIUM BATTERY BUILT IN INSTRUCTION LEAFLET Contains vital information on...

Страница 2: ...ht flashes at the same time it indicates the battery is depleted and the entire alarm must be replaced This normally occurs when over 10 years has elapsed 2 LOCATING YOUR SMOKE ALARM Sufficient smoke...

Страница 3: ...long one Smoke Alarm will not be sufficient This is because no matter where it is located it will be more than 7 5 metres from potential fires Recommended locations Figures 1 2 3 for minimum protecti...

Страница 4: ...occur for instance where there is an electrical appliance such as an electric blanket or heater or where the occupant is a smoker You could also consider putting Smoke Alarms in any rooms where the o...

Страница 5: ...d ceilings install your Smoke Alarm 0 9m from the highest point measured horizontally see figure 5 because dead air at the apex may prevent smoke from reaching the unit 3 4 Locations to Avoid Don t pl...

Страница 6: ...should get your family into a safe place before you start investigating Check the house carefully in case there is a small fire smouldering somewhere Check whether there is some source of smoke or fu...

Страница 7: ...ical wiring in the ceiling drill holes through the centres of the marked locations Push the plastic screw anchors provided into the drilled holes Screw in firmly 4 2 Connecting the built in Lithium Ba...

Страница 8: ...to 10 seconds Figure 7 The alarm will stop sounding shortly after the button is released If the alarm fails to sound follow this checklist Check the age of the unit see replace by label on base of un...

Страница 9: ...while cleaning Do not vacuum or brush inside the Smoke Alarm To clean the cover remove it completely and use only mild soap and water Dry cover thoroughly before replacing it WARNING Do not paint you...

Страница 10: ...End of life The entire Smoke Alarm must be replaced if i The unit is installed for over 10 years check the replacement year marked on the unit ii The unit is giving a short beep every 40 seconds and...

Страница 11: ...ential that all such openings including the wiring hole see figure 9 be closed by silicone sealant or similar After wiring together the Interconnect Smoke Alarms test the first unit by pressing the bu...

Страница 12: ...larm see Getting your Smoke Alarm Serviced page 15 This appliance is intended ONLY for premises having a residential type environment This is not a portable product It must be mounted following the in...

Страница 13: ...ton to familiarize your family with the Alarm sound and to practice fire drills regularly with all family members Draw up a floor plan that will show each member at least 2 escape routes from each roo...

Страница 14: ...mouldering cigarettes and ashes Service central heating systems regularly Be sure all electrical appliances and tools have a recognised approval label This device cannot protect all persons at all tim...

Страница 15: ...sed and the date of purchase FIVE YEAR GUARANTEE Limited Ei Electronics guarantees this product against any defects that are due to faulty material or workmanship for a five year period after the orig...

Страница 16: ...nt or to human health When disposing of this product please separate it from other waste streams to ensure that it can be recycled in an environmentally sound manner For more details on collection and...

Отзывы: