32
www.ehs-heating.com
Model
ALC1-
1PSY-6
ALC1-
1PSY-8
System Boiler
Model
ALC1-
1PCO-
12
ALC1-
1PCO-
14
Combi Boiler
Voltage
230V
Frequency
50Hz/60Hz
Phase
1
Power KW
6
8
12
14
Current A
31.8
36.4
54.5
61
Wire mm
2
4
6
10
16
Circuit Breaker A
32
40
63
63
Working Temp. Range
30°C~80°C (in radiator mode)
30°C~55°C (in Underfloor heating
mode)
Max. Water Temperature
85°C
Temperature Difference
5~20°C
Setting Range
Adjustable between 30 and 85°C
Antifreeze Start Temperature
<
8°C
Anti-freezing function stop temp.
≥
10
°C
Output Voltage of Pump
230V ac, 0.4A
Capacity of Expansion Tank
5L
Inlet & Outlet Connection
G1/2”
Flow and Return connection
G3/4”
Product Size EHS System Boiler
630mm*380mm*230mm
Product Size EHS Combi Boiler
630mm*380mm*230mm
12.
BOILER MAINTENANCE
EHS electric boilers do not require maintenance other than the following:
The heating system must be filled and maintained when the water is cold, between a pressure of 1 – 3 bar. Frequent
refilling of the system can cause scaling, corrosion and damage to a heating system and should be avoided wherever
possible. Regular pressure loss could be indicative of a leak within the system and should be investigated.
UNDER NO CIRCUMSTANCES SHOULD THE BOILER BE SWITCHED ON WHEN THE SYSTEM IS DRY.
The boiler contains an installed frost-protection program. For this to operate, power must be always supplied to the
boiler.
Anti-freeze can be added to the heating system (no more than 20% by volume) if the boiler is going to be stood
unused for long periods of time. Otherwise, the boiler should be disconnected from the electricity supply and the
system fully drained to avoid any frost damage.