5 Commissioning
Installation and Operating Instructions
High Pressure Cleaner, Hot Water, Stationary
HSC1140-INOX Gas
Check burner settings by qualified personnel according to Section 5.3,
Burner setting values for Gas Heated Systems and adjust if necessary:
For safety reasons after completion of cleaning work
○
Lock the trigger lever of the trigger gun against unintentional
switching on using the locking lever (4, Fig. 6-2). Ensure that the
locking lever is positioned in the notch (5, Fig. 6-2).
○
Switch off the system via the main Start - Stop switch on the cabinet
door front (move switch to position 0).
General Information
For the addition of detergents to the high pressure jet, see Section 6.4,
Use of Detergents (Chemistry).
Only qualified personnel authorised by the system operator can set and
specify the quantity of cleaning agent to be added inside the cabinet via
the detergent control valve.
The admixing of the cleaning agent can only be switched on/off at the
front of the cabinet door.
5.3
Burner setting values for gas-fired systems
WARNING
Use only approved fuels.
Only use fuels approved by the manufacturer. The use of other fuels
impairs the operational safety of the system and may endanger life and
limb of persons.
WARNING
Adjust gas burner properly.
For the burner setting of the gas-fired system depending on the system
configuration, observe the installation and operating instructions of
Weishaupt (gas burner WG5) or Baltur (gas burner BPM90).
Check the combustion values of the gas burner at the connected chimney.
The measured flue gas values must be within the limits listed below.
Indications for the burner setting
Fuel:
Natural gas H (Hu 10.4 kW/m³)
Gas pressure:
20 ... 25 mm WS flow pressure
Air compression:
medium compression