Technical data
3.3.1
Technical data of the system
Designation
Technical value
Unit
Performance data
Operating pressure water (with standard
nozzle)
3 ... 18 (30 ... 180)
MPa (bar)
Max. operating overpressure (safety valve)
20 (200)
MPa (bar)
Water flow rate (continuously adjustable )
300 ... 1000 (5 ... 16,6)
l/h (l/min)
Detergent suction
(continuously adjustable )
0-50 (0 ... 0,8)
l/h (l/min)
Pump speed
1400
rpm
Heating power
50
kW
Water connection
Inlet flow rate (min.)
1100 (18,3)
l/h (l/min)
Inlet pressure (min.)
0,1 (1)
MPa (bar)
Inlet pressure (max.)
0,6 (6)
MPa (bar)
Electrical connection
Voltage
3 / 400 - 415
V
Frequency
50
Hz
Current
11,7 A
A
Connected power
6,5
kW
Electrical protection (slow blow)
3 x16
A
Protection type
IPX5
-
Protection category
I
-
Maximum permissible mains impedance
(0,381+j 0,238)
Ohm
Electrical supply cable
H07 - RNF 5 x 1,5
mm
2
Temperature
Inlet temperature (max.)
30 - 70
°C
Max. operating temperature hot water
98
°C
Max. temperature safety thermostat
110
°C
Temperature increase at max.
water flow rate
60 ... 65
°C
Table 3 - 1
Technical data for HSC1140-INOX Gas