background image

2.1. 

  Safety Information

WARNING: In order to avoid overheating,  do  not cover  this appliance.

The appliance must not be  located immediately below  a socket"outlet.

To avoid burns, do  not  touch the  hot  surface of  the appliance  when  it  is in  use.

Do  not  run  the  power  cord  under  carpets,  rugs  or  runners  and  ensure  it  is  away

from  a  traffic area to avoid slips trips and falls.

Connect the  appliance  to  a  properly                           grounded  power outlets only.

Use  the  appliance  only  as  described  in  this  manual  as  any  other  use  which  is  not

covered  in  this  manual  may  cause  fire,  electric  shock,  injury  to  persons.

If  the  supply  cord  is  damaged  it  must  be  replaced  by  an  authorised  service  agent,  or  an

approved  competent  person  in  order  to  avoid  an  electric  shock  hazard.

Please do not place clothes or towels on  the  radiator  as this  will result  in  the  radiator over

heating.

Always use the appliance in an upright position, make sure the appliance is on a dry even surface.

Do not insert or allow foreign objects to enter any ventilation openings as this may cause an

electric shock, fire and/or damage to the appliance.

Do not use the appliance for any other purpose than its intended use.

Do not position the appliances in close proximity to curtains other combustible materials or

explosive objects, or objects which can be easily deformed or damaged

Keep combustible material such as furniture, cushions, soft furnishing, paper, clothes at least

1.0m away from the appliance.

Do not operate in areas where paints or flammable liquids are used or stored.

The appliance is not suitable for outside use

Do not use this heater in the immediate surroundings of a bath,shower or swimming pool.

If  this heater is to be installed in a room containing a bath or shower, it must be installed in such a

way that any that none of the controls or switches can be touched when using the bath or shower.

 

 

EHC 

4

EHC 

5

Содержание ELE1000.750.450

Страница 1: ...NSTALLATION OPERATING INSTRUCTIONS The Electric Heating Company Limited Unit 40 Block5 Third Road Blantyre Industrial Estate Glasgow G72 0UP Tel 01698 820 533 Fax 01698 825 697 info electric heatingcompany co uk www electric heatingcompany co uk EHC 1 ...

Страница 2: ...CONTENTS 1 General information 2 Safety information 3 Installation 4 Electrical Zones 5 Operating Instructions 6 Technical Dimensions EHC 2 ...

Страница 3: ...o come with a patented Magmatic heating tablet providing partial heat retention Whilst the radiator is classed as a 100 efficient Direct Acting appliance the heating tablets provide partial storage to prolong your heating comfort and to help reduce running costs The EHC Visage Glass Electric Radiators have the same internal components as the EHC Visage Radiator but have an ultra modern streamlined...

Страница 4: ...ied electrician Alternatively the mains cable can be cut to length by a Qualified Electrician and connected to a suitable 13A DP Switched Fuse Connection unit adjacent to the radiator This connection unit should comply with BS 1364 4 having a contact separation of at least 3mm Please ensure that the electricity supply is disconnected prior to using this installation method The installation of this...

Страница 5: ...over heating Always use the appliance in an upright position make sure the appliance is on a dry even surface Do not insert or allow foreign objects to enter any ventilation openings as this may cause an electric shock fire and or damage to the appliance Do not use the appliance for any other purpose than its intended use Do not position the appliances in close proximity to curtains other combusti...

Страница 6: ...d in a room containing a bath or shower it must be installed in such a way that none of the controls or switches can be touched when using the bath or shower RADIATOR REAR PANEL FIXING DIMENSIONS 85mm 35mm Min 150 mm Min 300mm from shelf Floor Min 100 mm Wall fixing information 1 Measure 185 mm min from the floor to the bottom of the wall bracket level the bracket and mark your drilling positions ...

Страница 7: ...d use the screws provided Where it is not possible to locate the studding use a recommended plasterboard fixing that is capable of withstanding the full weight of the heater Note The wall fixing manufacturer should be consulted to make sure the correct fittings are used for the wall type Optional Radiator Feet Visage Eligance heaters Excluding Glass can be mounted with free standing feet The appli...

Страница 8: ... a minimum of 3mm and in accordance with the current IEE Wiring Regulations The heater must not be installed immediately below a fixed socket outlet or any combustible object If multiple heaters are to be installed and plugged into the domestic socket ring circuit then considerations should be made in regards to the total circuit loading Note The Visage Elegance range of radiators are suitable for...

Страница 9: ...perature briefly press the or button and the digital display will show the thermostat temperature setting If you require the room thermostat temperature setting to be increased or decreased briefly press the or button until the desired room thermostat temperature setting is showing The digital display will flash approximately 4 times at 1 second intervals and then the digital display will stop fla...

Страница 10: ...ypically uses to have the radiator turn off The frost setting is normally set at 5 Celsius STEP 1 Setting the Desired Room Temperature Sun Setting Push the On Off button so that the symbol disappears and you can see the sun symbol at the top of the display Press or button to set the desired temperature Press the small information button below the i symbol on the display to see the actual current r...

Страница 11: ...ill see the triangle pointer moving to the next day Auto Program Overrides 1 Timer Mode A set temperature can be selected for a certain period of time Step 1 Step 2 Step 3 In the auto mode press the button below the hour glass once Set the desired temperature with the buttons below the and symbols then press the OK button to confirm Set how long the heater is required to be on with the buttons bel...

Страница 12: ... LCD Block indicates what temperature is active at that time Manual Mode The Set Temperature only changes if the user modifies it by pressing the and buttons OFF The radiator will not heat but can receive remote instructions if linked to a gateway that is connected to the internet Auto Mode Manual Mode Off Note When in Auto Mode manually adjusting the temperature will Activate the heater for 1 5 h...

Страница 13: ... The DSR controller has 3 temperature ranges Comfort Normally when at home Economy Normally used at night or for brief absence periods Frost Protection Normally used when away from home To Set Temperatures to exit Now Press Select your temperature change by pressing the buttons then press to confirm Once you have chosen your temperature ranges press At Work Away EHC 13 ...

Страница 14: ...Once you have programmed a 24 hour period will automatically move onto the the next day Now program all 7 days in this way Once all 7 days are programmed the controller will then ask you to select the Day of the week 1 being Monday Select by pressing the and buttons Save by pressing the OK button The next stage is to set the real time Use the and buttons to select the Hour s and Min s save by pres...

Страница 15: ...ave C1 Factory Defaults Mode OFF Tª comfort 19ºC Tª eco 17ºC Tª freeze 5ºC Tª mode manual 19ºC Temperature compensation Offset 0ºC No RF link Temperature units ºC Open window detection OFF Control mode PID TRIAC PID15 Relay Program All hours Eco C1 Temperature unit adjustment ºF ºC C2 Heating control type adjustment PID15min or PID30min Factory Set Do Not Change C3 Temperature compensation adjustm...

Страница 16: ...ised the Gateways LED s will begin to flash Orange ON alternating Green every 5seconds means you are connected Note If this doesn t happen check LED sequence list below Gateway LEDs Status Green off Orange flashing one second discovery status device pairing Orange on Green flashing 0 2 seconds the router has not assigned an IP address to the gateway Orange on Green flashing briefly every 5 seconds...

Страница 17: ...a device at this stage For each additional new device that is added the available time increases as you go through the pairing process Pairing a Heater with the Gateway When the Gateway is in pairing mode Simply press and hold the OK button on the heater for 3 your heater is now connected and ready to program seconds until the Link symbol appears through the App 9 0 Optional Power Meter Note Insta...

Страница 18: ... Terminals when connecting the power cable to the Meter Typical Layout TEST 6 3A FUSE Consumer Unit Main Cable to Property Earth not shown for clarity Fused Spur Mini Enclosure Pairing the Power Meter You can simply pair the power meter in the same way as you would a heater by putting the gateway into Pairing Mode Once the Gateway has been activated and is in the Pairing Mode press the small butto...

Страница 19: ...onsumption metering 3 error Transformer less power stage Max power 16A Gateway External Power Supply Voltage 5V 500mA Consumption 300mA Connector Type RJ45 Ethernet connector LED indicator conditions 868Mhz RF integrated PCB antenna Micro USB Adaptor included Ethernet 0 5m cable included Power Meter DIN Rail Mount mini enclosure required External current sensor 3 5 mm jack connector for easy insta...

Страница 20: ...ody of the radiator The period of guarantee commences from the day of delivery If within the guarantee period the radiator is defective due to faulty components we undertake to repair the radiator free of charge The guarantee shall not apply to damages caused by natural wear and tear intentional misuse non observance of the operational instructions connection to incorrect supply voltage damages ca...

Страница 21: ...Telephone 01698 820533 Fax 01698 825697 E mail info electric heatingcompany co uk Or visit our website www electric heatingcompany co uk EHC 21 ...

Отзывы: