Keypad Locking
4
.
Operation Instructions
DSR Wif
i
Page 1
7
LOCK
Press and Hold the
+
and
-
buttons for 3 seconds to Lock the key pad. All the
buttons will be disabled if pressed. ( LocH will be displayed )
7RXQORFNSUHVV
DQGKROGWKHDQG%XWWRQV
for 3 seconds.
Configuration Settings
5.
0
Advanced Engineer Settings
To enter advance settings,
1.
Press the Config button Once
to show this screen
2.
Now press and hold the Config button for 5 seconds, C1
will now
A
ppear
3.
Change
C
onfiguration Number by pressing the
+
or
-
buttons, then press
OK
4.
Change the
C
onfiguration by pressing the + or - button
,
Then
OK
to save.
C1
Factory Defaults
Mode: OFF
Tª comfort: 19ºC
Tª eco: 17ºC
Tª freeze: 5ºC
Tª mode manual: 19ºC
Temperature compensation Offset: 0ºC
No
RF link
Temperature units ºC
Open window detection: OFF
Control mode: PID -TRIAC-, PID15 -Relay-
Program: All hours Eco
C1: Temperature unit adjustment ºF/ ºC
C2: Heating control type adjustment
PID15min or PID30min (Factory Set Do
Not Change)
C3: Temperature compensation
adjustment
C4: Firmware version
C5:Open window detection activation
(stops
the heating for
30
if a fall of 2,4ºC
is detected
over a period of 4
minutes)
Reset
Heater to Factory Settings
Press and Hold
Config
&
OK together
for 10
Seconds,
rES
will show on display, Confirm by
pressing
OK
Note
:
Advanced settings should only ever be changed by a fully qualified
engineer
or with advice from EHC.