EHC DSR Smart Gateway Скачать руководство пользователя страница 1

The 

Combination

 Range of 

Electric

 Radiators

The Electric Heating Company Limited

 Unit 40 

,Block 5, 

Third Road, 

Blantyre Industrial Estate, 

Glasgow

G72 OUP 

Tel

:

 01698 820533 

[email protected] 

www.electric-heatingcompany.co.uk

the electric heating company

INSTALLATION 

OPERATING INSTRUCTIONS

 

THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED 

FOR FUTURE REFERENCE. 

BE SURE TO OBSERVE ALL LABELS AND WARNINGS ON THE 

APPLIANCE.

Fax: 

01698 820533 

Содержание DSR Smart Gateway

Страница 1: ... Estate Glasgow G72 OUP Tel 01698 820533 info electric heatingcompany co uk www electric heatingcompany co uk the electric heating company INSTALLATION OPERATING INSTRUCTIONS THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE BE SURE TO OBSERVE ALL LABELS AND WARNINGS ON THE APPLIANCE Fax 01698 820533 ...

Страница 2: ...REEN YELLOW EARTH BLUE NEUTRAL BROWN LIVE WARNING THIS APPLIANCE MUST BE EARTHED The installation of this appliance should be carried out by a competent electrician in accordance with I E E Regulations for Electrical Equipment The radiator is fitted with a standard UK 3 pin plug that can be directly connected to an electrical socket Care must be taken when connecting radiators in this way not to o...

Страница 3: ... Box Single or twin Zone Programmer s and Room Thermostats to comply with the latest Building Regulations In addition to the above we also supply Radio Frequency controlled radiators which provide all the benefits of the standard version however the control wiring is eliminated These models can be controlled by our T Pod and T Basic Programmers Also available is our TDI range of Electric Radiators...

Страница 4: ...ering installed on top of it 150 mm Cover plate non combustible covering installed on top of it 100 mm Please note that our IPX4 rated models should be used in bathrooms Portable radiators must not be fitted in bathrooms or wet areas CAUTION This radiator must not be located below or in front of a fixed socket outlet DO NOT POSITION under windows where curtains may contact the radiator DO NOT PLAC...

Страница 5: ...ting brackets four suspension hooks a set of mounting screws plugs and an instruction manual 20 cm 37 cm 50 cm 67 cm 80 cm 110cm 140 cm Rad Length cm 38 55 68 85 98 128 158 Bracketseparation cm 20 37 50 67 80 110 140 Page 4 Note Setting the brackets to the Minimum recommended 18cm to the lower fixing point will leave a distance of approx 8 7cm from the floor to the bottom of the heater 38 55 68 85...

Страница 6: ...the studding use Hollow wall anchors and securely fasten the brackets to the plasterboard when this method is used we recommend that radiator feet are used to take the full weight of the radiator For other wall materials the wall panel manufacturer should be consulted for details of suitable wall fixing devices Note Radiators will be set to an approximate height of 185mm from the floor when suppor...

Страница 7: ...RTHED For each supply a means for disconnection must be incorporated in the fixed wiring by a double pole switch with a contact separation of a minimum of 3mm and in accordance with the current IEE Wiring Regulations The heater must not be installed immediately below a fixed socket outlet or any combustible object If multiple heaters are to be installed and plugged into the domestic socket ring ci...

Страница 8: ...L 4 1 2 A1 A2 3A Radiator Radiator Radiator 3 Installation Single Zone Wiring Control wiring to be 1 5mm Twin Earth cable Radiator wiring should be a minimum of 2 5mm Twin Earth cable Page 7 7 ...

Страница 9: ...E 1 RADIATOR ZONE 2 RADIATOR ZONE 2 RADIATOR L 3 4 A1 A1 A2 A2 1 1 2 2 3 Installation Twin Zone Wiring 3A Control wiring to be 1 5mm Twin Earth cable Radiator wiring should be a minimum of 2 5mm Twin Earth cable Page 8 8 ...

Страница 10: ...hermostat and receiver in T RF located on the radiator according to the instructions included in the T Basic packaging Set the required temperature by adjusting the buttons 11 TDI Installations a b Follow the instructions outlined in section 7 for single radiator installations Configure the TDI Digital Control Display according to the instructions on page 12 13 of this manual Set the to set the ra...

Страница 11: ...ls Easy to use Temperature range from 5 C till 30 C Integrated temperature sensor Frost protection setting 2 x LED display lights Operating display lights OFF 5 C 10 C 20 C 25 C 30 C 15 C Radiator is ON Power going to the tablets Radiator is ON No power going to tablets Radiator is OFF Page 10 ...

Страница 12: ...ired room temperature briefly press the or button and the digital display will show the thermostat temperature setting If you require the room thermostat temperature setting to be increased or decreased briefly press the or button until the desired room thermostat temperature setting is showing The digital display will flash approximately 4 times at 1 second intervals and then the digital display ...

Страница 13: ... is the setting the user typically uses to have the radiator turn off The frost setting is normally set at 5 Celsius STEP 1 Setting the Desired Room Temperature Sun Setting Push the On Off button so that the symbol disappears and you can see the sun symbol at the top of the display Press or button to set the desired temperature Press the small information button below the i symbol on the display t...

Страница 14: ...day Your previous settings are now copied to the next day Auto Program Overrides 1 Timer Mode A set temperature can be selected for a certain period of time Step 1 Step 2 Step 3 In the auto mode press the button below the hour glass once Set the desired temperature with the buttons below the and symbols then press the OK button to confirm Set how long the heater is required to be on with the butto...

Страница 15: ...ted Each LCD Block indicates what temperature is active at that time Manual Mode The Set Temperature only changes if the user modifies it by pressing the and buttons OFF The radiator will not heat but can receive remote instructions if linked to a gateway that is connected to the internet Auto Mode Manual Mode Off Note When in Auto Mode manually adjusting the temperature will Activate the heater f...

Страница 16: ...Sleeping The DSR controller has 3 temperature ranges Comfort Normally when at home Economy Normally used at night or for brief absence periods Frost Protection Normally used when away from home To Set Temperatures to exit Now Press Select your temperature change by pressing the buttons then press to confirm Once you have chosen your temperature ranges press At Work Away ...

Страница 17: ...oller 4 Once you have programmed a 24 hour period will automatically move onto the the next day Now program all 7 days in this way Once all 7 days are programmed the controller will then ask you to select the Day of the week 1 being Monday Select by pressing the and buttons Save by pressing the OK button The next stage is to set the real time Use the and buttons to select the Hour s and Min s save...

Страница 18: ... OK to save C1 Factory Defaults Mode OFF Tª comfort 19ºC Tª eco 17ºC Tª freeze 5ºC Tª mode manual 19ºC Temperature compensation Offset 0ºC No RF link Temperature units ºC Open window detection OFF Control mode PID TRIAC PID15 Relay Program All hours Eco C1 Temperature unit adjustment ºF ºC C2 Heating control type adjustment PID15min or PID30min Factory Set Do Not Change C3 Temperature compensation...

Страница 19: ...n energised the Gateways LED s will begin to flash Orange ON alternating Green every 5seconds means you are connected Note If this doesn t happen check LED sequence list below Gateway LEDs Status Green off Orange flashing one second discovery status device pairing Orange on Green flashing 0 2 seconds the router has not assigned an IP address to the gateway Orange on Green flashing briefly every 5 ...

Страница 20: ... to add a device at this stage For each additional new device that is added the available time increases as you go through the pairing process Pairing a Heater with the Gateway When the Gateway is in pairing mode Simply press and hold the OK button on the heater for 3 your heater is now connected and ready to program seconds until the Link symbol appears through the App 9 0 Optional Power Meter No...

Страница 21: ...mage the Terminals when connecting the power cable to the Meter Typical Layout TEST 6 3A FUSE Consumer Unit Main Cable to Property Earth not shown for clarity Fused Spur Mini Enclosure Pairing the Power Meter You can simply pair the power meter in the same way as you would a heater by putting the gateway into Pairing Mode Once the Gateway has been activated and is in the Pairing Mode press the sma...

Страница 22: ... self consumption metering 3 error Transformer less power stage Max power 16A Gateway External Power Supply Voltage 5V 500mA Consumption 300mA Connector Type RJ45 Ethernet connector LED indicator conditions 868Mhz RF integrated PCB antenna Micro USB Adaptor included Ethernet 0 5m cable included Power Meter DIN Rail Mount mini enclosure required External current sensor 3 5 mm jack connector for eas...

Страница 23: ...p and ends of the radiator Do not allow furniture to be pushed up against the radiator A minimum clearance of 150mm is critical for safety however to ensure radiator performance is not affected a clearance of 250mm is recommended DO NOT PLACE OBJECTS IN CONTACT WITH THE RADIATOR CAUTION The radiator must not be located below or of in front of a socket outlet PLEASE NOTE THIS RADIATOR IS HEAVY AND ...

Страница 24: ...ights under common law Should you require after sales assistance please contact the EHC Help Desk on 01698 820533 Conditions of Guarantee EHC Electric Radiators We are pleased to offer a 15 year guarantee on your recent purchase of EHC Electric Radiators The 15 year guarantee applies to the heating elements and body of the radiator A 2 year guarantee is applicable to the electronics The period of ...

Страница 25: ... mm mm Depth Weight mm kg White 4094 380 1240 70 35 EH1200 38 124 EH1800 55 124 1200W ELECTRIC RADIATOR 1800W ELECTRIC RADIATOR White 6142 550 1240 70 58 Bathroom radiators IPX4 Colour Rating Width Height Model No Description BTUs mm mm Depth Weight mm kg 2047 380 630 70 22 3412 680 630 70 36 EH 600 38 63IPX4 600W ELECTRIC BATHROOMRADIATOR EH1000 68 63IPX4 1000W ELECTRIC BATHROOM RADIATOR White Ac...