30.
3
Creating a group and giving it a number
If NO groups have been created yet:
GENERAL
(And the sign “ < “ appears next to
GENERAL) +
If the general access password is NOT active:
NEW
yES
2
Labelling the zones with names
If NO groups have been created yet:
GENERAL
(And the sign “ < “ appears next to
GENERAL) +
ZONE
If three zones -for instance- have been previously
created:
ZON 001
(And the sign “ < “ appears next to
ZON 001) +
If the general access password is NOT active:
NAME
>>>
(the cursor is placed in letter “
O
”) +
+
(“
O
” is replaced by “
P
”) +
hERE
gives to the control console 1202 the
zone number 1 (the console needs a zone number
only if it must be ready to receive messages).
ZONE SET
When pressed, the system is ready
to assign number 1 to a zone, and all the “zone set”
led lamps of the devices which can be given a zone
number will blink. If, in the mentioned devices, one
of the zone set buttons is pressed, that specific
device will be identified as zone nr. 1, and the
system will get ready to assign number 2 to the
following device / zone.
By following this procedure we can give consecutive
numbers to all the zones of the installation without
going back to the console 1202 (this is useful for the
initial configuration of the installation).
It is also possible to select a specific zone
number by pressing
+
or
–
and, after
pressing
ZONE SET
and following the ZONE
SET button of the corresponding device, the
selected number will be given to that device (this
is useful to replace an old device by a new one
which must have the same zone number without
repeating the set up procedure).
When a zone number has been assigned to all the
zones of the installation, we will quit the labelling
procedure and all the ZONE SET led lamps of the
different devices will stop blinking.
Now it is recommended to start up the system
(point nr. 13) prior to label the zones with names.
If the general access password is active the system will require us to introduce it every time we try to operate one of
the advanced functions (see point 2 of “
Access restrictions
”).
1202
Control console. Advanced functions
1
Giving a number to each zone
This is the first thing that has to be done in order to
configure a system (and it does not have to be done
again if the system configuration is not modified).
Provided that no groups have been created yet:
SETUP
If the general access password is NOT active and
there is NEITHER a pre-recorded message player
(1103) NOR a module for sending messages over
the telephone (1104) in the system:
ZONES
ZONE SET
cancels all the numbers that have
been given to the zones until pressed.
+