Configuration
The EZ-3u is ready-to-run; simply connect a suitable trigger and desired outputs, then set the PRE, RUN, and
OFF stage potentiometers as required for the prop or display. Another feature of the EZ-3u that sets it apart
from similar controllers is the ability to configure the timing span for each potentiometer, as well as the pulse
output timing.
IMPORTANT:
Disconnect any devices controlled by the Pulse or Audio outputs before entering the
configuration mode.
•
Power up (position 1) with configuration jumper installed; wait for flashing PRE LED.
•
While PRE LED is flashing, set PRE pot to desired zone. Press START to set
•
While RUN LED is flashing, set RUN pot to desired zone. Press START to set.
•
While OFF LED is flashing, set OFF pot to desired zone. Press START to set.
•
While PULSE LED is flashing, set RUN* pot to desired zone. Press START to set.
•
When all LEDs flash, your settings are saved. Power down and remove configuration jumper.
* Note: Setting the Pulse timing uses the RUN pot.
Zone A
Zone B
Zone C
Zone D
Zone E
PRE Delay
( 0-10s )
0-20s
0-30s
5-15s Random
10-30s Random
RUN Time
10-30s
( 10s-1m )
10s-2m
10s-3m
10s-5m
OFF Time
10-30s
( 10s-1m )
10s-2m
10s-3m
10s-5m
PULSE / Audio
( 0.25s )
0.50s
1.00s
2.50s
5.00s
Values in parenthesis ( ) denote factory settings for PRE, RUN, OFF, and PULSE timing