background image

Trigger Inputs

The EZ-3u provides four options for triggering its operational cycle:

Dry contact (button, mat switch, etc.) terminal (E)

12 to 24 VDC input from another controller (F)

PIR (G)
– 3-pin header provides power and signal connections for Parallax-compatible PIR sensor

START button (H)

All inputs are active and may be used together if desired. 

Relay Outputs

The EZ-3u provides normally-open and normally-closed relay outputs for the period of the run cycle. These 
terminals are capable of switching AC or DC up to 5A.

Pulse Outputs

Unique to the EZ-3u are the pulse outputs that are active at the beginning of the run cycle.

High-current, open-collector DC output (L) for valves and relays

Low-current, open-collector or 5 VDC output (M) for audio players
– output set with configuration jumper (N)

The high-current output terminal is designed for use with valves, relays, LEDs, and other DC devices. The 
positive side of the device is connected to the V+ terminal, the negative side of the device is connected to the 
PULSE terminal. 

The low-current AUDIO output header may be configured for Open-Collector (OC) or 5 VDC output. The 3-pin  
audio header provides ground (B pin), 5 VDC (R pin), and selected pulse signal (W pin).

EZ-3micro Operation

As with traditional 3-stage timers, the EZ-3u waits for a trigger signal. When a trigger input is detected, the  
PRE delay timing is started; during this period the PRE delay LED (yellow) will light. When the pre-delay  
timing is complete the RUN timing is started; during this period the RUN time LED (green) is lit and the on-
board relay is active. When the run timing is complete the relay is deactivated and the OFF timing is started;  
during this period the OFF time LED (red) is lit and the EZ-3u will ignore its trigger inputs. At the completion of 
the off-timing period, the red LED will extinguish and the EZ-3u is ready for another trigger input.

What makes the EZ-3u unique is the addition of pulse output signals that occur at the beginning of the run  
cycle. These outputs can be used to run a short-duration DC output (PULSE terminal) or to start an external  
audio player (AUDIO terminal).

The illustration on the following page visually describes the sequential operation of the EZ-3u on detecting a 
trigger input.