Product:
Project:
UV BARx1 version 2.2
2201075
Page:
Latest updated:
9 af 12
30.07.2020
www.efsen.dk
i.
Place the non-plug end of the new UV lamp to the metal clamp first.
j.
Then insert the 4 pin connector by gently pressing it downwards
until it clicks into fixed position.
k.
Check that the UV lamp works by starting UV BARx1
(Attention! Be protected from UV light and turn the lamp away
from persons).
3.
Disposal of UV lamps
a.
UV lamps contain a small portion of Mercury, so they must be disposed accord to the
local legislation, for example at the local recycling station.
4.
Broken UV lamps / Damaged UV lamps
a.
If an accident happens and the UV lamp breaks, then do not touch glass or any other
residue with bare hands. Be aware that UV lamps contains mercury or amalgam.
b.
Make sure to have ventilation in space - open window or door.
c.
Gently push bigger parts onto a dustpan. Use adhesive tape to
pick up small parts and residues of the bulb filling. Do never
use a broom or a vacuum cleaner to pick up small parts.
d.
Dispose of the plastic bag and contents correctly on local
recycling station.