PHASE
DESCRIPTION
FINAL CLEANING
The thermo-stove is in the off phase and the cooling phase has not yet been completed
IGNITING
The candela preheating stage has been started, and pellets are beginning to fall into the brazier
FLAME WAIT
Pellets will ignite using the heat of the intake air passing through the incandescent resistor conduit
FLAME PRESENT
A flame can be seen in the brazier
WORK
The thermo-stove has completed the switch-on phase
MODULA WORK
The room temperature/ boiler water temperature set point has been reached.
ECO STOP
Comfort Climate activated, room temperature set point reached (air), or “Water temp set point +
delta comfort climate” (water). The thermo-stove is off
T ON
The room sensor is not working or an external thermostat is connected
VENTILA WAIT START
The thermo-stove is in the cooling phase: once this condition has been reached, it starts
automatically
VENTILA WAIT
RESTART
The thermo-stove is in the cooling phase: once this condition has been reached, it restarts
automatically
SWITCH ON RESTART
WAIT
The hot restart phase has been started. Operation is similar to that in the SWITCH-ON phase
HOT SMOKE
The maximum threshold has been reached: for cooling, the thermo-stove reduces the pellet load to
PT 01 and keeps a PT 05 draught
WATER STAND-BY
A water temperature of 85°C has been reached. The thermo-stove automatically switches to
STAND-BY mode to ensure hydraulic circuit protection
OFF
The thermo-stove is off
Switch-on or Flame Wait
PELLETS RUNNING OUT
When a power-on after ECO-STOP is near an automatic switch-off (from TIMER), the thermo-stove
ensures complete cleaning of the basket before switching to FINAL CLEANING
Synthetic scheme of phases
Optional Remote Control
IR remote control to remotely operate the thermo-stove
Operational warnings
• Switch off the thermo-stove in case of failure or improper operation using the P3 key.
• Do not put pellets manually into the brazier.
• The unburnt pellets built up in the brazier must be removed before switching on the thermo-stove again.
• Do not put fuel other than wood pellets into the fuel tank.
• Do not switch on the thermo-stove using flammable materials in case of falure of the switch-on system.
! IMPORTANT
IF “HOT SMOKE” IS DISPLAYED, THERE ARE COMBUSTION PROBLEMS. PLEASE CONTACT
YOUR LOCAL TECHNICAL SUPPORT CENTRE FOR AN INSPECTION
4
3
5
6
1
2
• 1 - 2 Temperature adjustment
:
allows setting the room temperature value desired, from
a maximum of 40°C to a minimum of 6°C.
•
5 - 6 Power adjustment
:
allows setting the work power value from a minimum
value of 1 to a maximum value of 5.
• 3 ON/OFF:
if pressed for two seconds, the stove can be manually
switched on and off
.
• 4 With no function