Model Aqva 18 Use and Maintenance Manual
Page55
Rev.3 14/11/2017
EN
This type of installation (See Fig.6) requires a horizontal section to connect to a pre-existing chimney pot.
Respect the slope indicated in figure, in order to reduce the ashes depositing in the horizontal tube. In the lower part of the chimney
as well as on the chimney opening, there is a "T" type fitting with an inspection cap.
It is prohibited to install a 90° bend for the initial segment, since the ashes would quickly obstruct smoke passage, causing draught
problems in the stove. (See Fig.2)
2 - 3 mt max
Height exceeding 4 mt
Slope 3 - 5 %
Max 2 - -3 mt
INTERNAL
CHIMNEY
Fig.6
T fitting for condensation
Inspection hatch
Protection from rain
IT IS MANDATORY TO USE STAINLESS STEEL AIR-TIGHT PIPING WITH SILICONE OR VITON
®
GASKETS.