Electronic device DMU2000 - DMU3000 - DMU3000 PLUS
THE POWER OF PERFORMANCE
1
Electronic device DMU2000 - DMU3000 - DMU3000 PLUS
4
Pressure 100% 2nd boom cylinder
When this pressure value inside the second boom cylinder is achieved, the load limiting device is oper-
ated.
5
Pressure 100% additional jib cylinder
When this pressure value inside the jib cylinder is achieved, the load limiting device is operated.
6
% Downgrading 1st boom cylinder to work in B area
By changing this value, you change the crane performance relating to the front work area. Performance
is expressed as a percentage of the crane maximum lifting capacity .
NOTE:
On crane models fitted with an encoder to determine the position of the crane booms with
respect to the truck longitudinal axis, zero is displayed instead of the value originally set, and to make
a change in performance in B Area, you should use the appropriate software interface called “SERVICE
MANUAL, edit stability parameters.
7
Cancel performance
downgrading in B area
If the installation of the crane does not require any identification of the area
“B”,
related to performance
downgrading, if you select “
OFF
” you cancel this function.
NOTE:
We recommend not setting the front working area by 100%, as the load limiting device opera-
tion would lead to func
tional restrictions relating to the manoeuvrability of the crane upper booms
owing to the off selection (e.g. when it comes into operation no rise manoeuvre with the crane booms
is allowed). If you must reverse the position of working area “A” with the position of the work area “B”,
you must operate mechanically cr
anes by moving the proximity switches or the cam: this change in
position is not possible using the DMU.
NOTE:
Crane models fitted with an encoder to determine the position of the crane booms with respect
to the truck longitudinal axis, OFF appears and you cannot change it. In order to cancel performance
downgrading in B Area, you should use the appropriate software interface called “SERVICE MANUAL,
edit stability parameters“.