Overheating protection

Cuts power when the temperature exceeds 95ºC

2

Display

Status of the heating system

2

Keypad

Maneuvering in the menus

▀  

Control panel

Содержание Pellets 222

Страница 1: ...Rev JG 013 02 04 EFFECTA PELLETS 222 INSTALLATION MAINTENANCE SERVICE ASSEMBLY ...

Страница 2: ...our own judgement when operating the pellet boiler Remember that the hatches and some surfaces can get hot You must take caution to avoid being burnt The user It is the user s responsibility to operate the boiler according to our instructions If you do not operate and maintain your boiler correctly the environmental impact of the boiler will be greater it s efficiency will be reduced and the servi...

Страница 3: ...cta before starting any servicing work You must submit your complaint without delay You must always state the type of product the date of purchase and the serial number Otherwise the heating and plumbing industry s current regulations apply in case of complaints Guarantee terms The guarantee is valid on condition that The boiler and the heating system have been installed in accordance with the ins...

Страница 4: ...nstaller 6 Boiler room 6 Chimney 6 Set up 6 System components 7 Shunt valve 7 Valve combination 7 Overheating protection 7 Micro switch 7 Seal 7 Cleaning 7 Flue gas temperature 7 Control panel 8 Placement of the components 9 Service and cleaning 10 Automatic cleaning 11 Hot water 12 Valve combination 12 Shunt valve 12 Cleaning 13 Electrical connection 14 Electrical connection 15 Electrical connect...

Страница 5: ...eans that extra caution should be taken Otherwise serious personal injury might occur When maintaining the product where this symbol is present the power must be disonnected All electrical wiring must be done by a proffesional This product manual is a living document You will always find the latest verion on our webpage www effecta se Type plate 2012 2012 2013 2014 2015 Tillverknings år Manufactur...

Страница 6: ...e fitted with ignition protective covering and the floor must be made of non combustible material Minimum ceiling height at the boiler is 2 metres The boiler room or boiler house must be equipped with a fresh air intake with the minimum dimensions 150 x 150 5 mm or with a sufficiently large free sectional area to avoid low pressure in the boiler room It must be impossible to close the air intake C...

Страница 7: ...ro switch stops the auger alt the whole burner depending on installed burner if the ash door is open It s important that this functions works and is checked regurlarly The sealings The seals on the hatches must be checked every year If the hatches do not seal properly the efficiency and the combustion process of the boiler will deteriorate Control panel The functions of the control panel should be...

Страница 8: ...gdalsvägen 21 434 99 Kungsbacka 46 0 300 22320 info effecta se 8 1 Overheating protection Cuts power when the temperature exceeds 95ºC 2 Display Status of the heating system 2 Keypad Maneuvering in the menus Control panel ...

Страница 9: ...1 Drain 2 Soot door 2 Cable gland 2 Return hotwater 3 Microswitch inside the door 3 Valve combination 3 Cable gland 4 Handle 4 Shuntvalve 5 Hole for burner 5 Lid 6 Control panel 6 Expansion hotwater 7 Power for burner 7 Hole for measuring instrument 8 Flame sensor 9 Power for auger Placement of the components Only with Effecta Supra Aero ...

Страница 10: ...fecta Supra read more about service and cleaning in the burner manual Cleaning of the convection part Clean the tubes with the supplied brush follow instructions how to remove the turbulators on pg 13 It s important for the boilers efficiency that these are cleaned thoroughly at the service Cleaning of sootbox and fluetube Soot box which is placed above the tubes must be emptied of ash if the soot...

Страница 11: ...ulled up and down Automatic cleaning system optional Function and service Cut the power to the boiler before servicing The magnet motor is mounted on the boiler to keep the convective part clean It is controlled from the menu Cleaning on the control panel It can be set to work not work in different times during the day Suspensions On every suspension there are three turbulators that is removed whe...

Страница 12: ...as desired for larger amounts When hot water is prepared in a coil legionella bacteria cannot occur Valve combination The valve combination is there so the hot wa ter temperature doesn t get to scalding tem perature In order to increase the temperature turn 1 against You may also need to tune the flow valve 6 to reduce the flow through the coil There is a safety valve 9 that releas es the water ou...

Страница 13: ...below Start by removing the lid on the top of the boiler 1 Then loosen the two nuts 2 and remove the hatch 3 Lift up the two suspensions with turbula tors 4 Clean the tubes with the brush The ash compartment 5 is normally cleaned after about 1 5 tons consumption of pellets Note that there can be glow a long time after burning 1 Lid 2 Nuts 3 Soot hatch 4 Suspension turbulators 5 Ashbox inside of th...

Страница 14: ...Solenoid valve AERO 2A 230 VAC PE Earth N Zero 15 Compressor 2A 230 VAC PE Earth N Zero 16 Magnet motor tube cleaning 2A 230 VAC N Zero 17 Loading pump 2A 230 VAC Remember to always cut the power to the boiler before starting any work on it All electrical work should be done by a certified electrician for everyo nes safety Change of e prom Cut the power to the boiler Remove the front panel on the ...

Страница 15: ...EL 2a EL 2b EL 1b EL 1a L2 L2 E PROM M TUBE CLEANING M BLUE BROWN YELLOW GREEN L3 EL 3a EL 3b L3 51 52 53 54 55 56 57 58 AMPERE METERS JOINT 1 2 3 4 5 OUT DOOR SENSOR RC 482 Display YELLOW GREEN BROWN BLUE SOLENOID VALVE 24 23 22 21 N YELLOW GREEN M FAN MOTOR IGNITOR O H PROTECTION FALL SHAFT EARTH CENTER SOCKET EARTH CENTER PIN FEEDER MOTOR PALE BLUE 6 2 5 4 3 1 M ELSCHEMA EFFECTA 222 MED SUPRA E...

Страница 16: ...cal installation Load limiter If the electrical use in the facility is high at the same time as the eletrical heater in the boiler is running there is a chance that the main fuses trips Effecta Pellets 222 is equipped with a load limiter which distributes the power between the phases or disconnects if there is a overload on any of the phases Current sensor To measure the current a current sensor i...

Страница 17: ...s mantle Shhet tickness combustion Ash compartment volume Ash compartment depth Max effect Max operating temperature 690 mm 740 mm 1560 mm 240 kg 1 5 bar 150X150 mm 126 mm 1630 mm 192 liter 15 pa 120 mm 230 380 VAC 4 mm 4 mm 106 liter 510 mm 20 kW 99 gr 4 5 535 690 158 223 740 415 500 1456 164 350 630 150 1545 1702 690 2 1 3 3 NYA EFFECTA LAM 010 08 15 V E A TEKNISK DATA 1 FRAMLEDNING 2 RETURLEDNI...

Страница 18: ...300 22320 Fax 0300 22395 E post info effecta se www effecta se 012 06 20 V50 05 93 E A EXPLANATIONS 8 1 ROOM THERMOSTAT OUTDOOR THERMOSTAT BOTH 2 RADIATOR VALVE 3 RADIATOR PUMP 4 REFILL 5 SHUNTVALVE WITH MOTOR 6 MIXING VALVE 7 EXPANSION VESSEL WITH SAFETY VALVE1 5BAR 8 DRAIN PLUGS 9 DIRT FILTER RADIATORS 3 7 4 5 2 1 2 WATER MEASUREMENT DOMESTIC WATER 9 6 PRINCIPAL SCHEME EFFECTA 222 WITH HOT WATER...

Страница 19: ...y when the hatch is closed Then fasten the screws Adjusting the draft By moving the counterweight along the balance shaft the draft needed to open the hatch is adjusted About 1Pa per 2mm fig 2 The hatch is preset at about 1Pa A professional should measure the draft and make the adjustments Functions Tigex draft stabiliser opens the hatch just as much as needed depending on the current draft The dr...

Страница 20: ...t water capacity Low boiler temp Ti high flow in the pipes system Set the burners stop temp higher Adjust the flow on the mixing valve Soot in the boiler room Leaking seals Check seals contact installer High flue gas temperature Sooty boiler Poor combustion Broken sensor Clean boiler Contact installer Contact installer White smoke from the chimney Low flue gas temperature To big chimney Rainwater ...

Страница 21: ... Värmepanna för pellets Nummer 01 756697 01 Direktiv 89 336 EEG med tilläggen 92 31 EEG 93 68 EEG EMC 73 23 EEG med tillägget 93 68 EEG LVD 97 23 EC PED Harmoniserande standarder SS EN 60204 1 Elektrisk utrustning för industrimaskiner Del 1 Allmänna fordringar Kopplat till maskin och LVD SS EN 50081 2 För emission industri EMC standard SS EN 50082 2 För immunitet industri EMC standard Kungsbacka 2...