The Boiler

Effecta Complete is a boiler which is to be fueled with wood pellets. No other kind of fuel is 

allowed to be used. Not logs or oil.

Disassembly and disposal

It will be many years before your Effecta boiler is worn out, but it is important that you follow 
the regulations in force at the time concerning disassembly and disposal of your boiler.

The fuel

The boiler should normally burn 6/8 mm fuel pellets which come either in 16 kg sacks or 
are supplied by bulk truck. If you have built a bulk storage container, you should follow the 
current recommendations to ensure that the quality of the pellets does not deteriorate. Never 
use pellets which do not meet European pellet standards, as this may result in problems in 
operating the burner.

▀  

In general

Information

This symbol is shown with info to the installer which can be important to know and 

understand. Neglecting these informations can be harmful to the prestanda in the product.

▀  

Symbols in this document

Warning

This symbol is shown when the installer or user must be careful in the handling of the 

product. Neglecting these warnings can result in damage to the product or personal injury.

Dangerous electricity

This symbol means that extra caution should be taken. Otherwise serious personal injury 

might occur. When maintaining the product where this symbol is present the power must 

be disonnected. All electrical wiring must be done by a proffesional.

Содержание Komplett

Страница 1: ...Rev JG 012 01 02 INSTALLING MAINTENANCE SERVICE ASSEMBLY EFFECTA KOMPLETT...

Страница 2: ...llet boiler Remember that the hatches and some surfaces can get hot You must take caution to avoid being burnt The user It is the user s responsibility to operate the boiler according to our instructi...

Страница 3: ...ta before starting any servicing work You must submit your complaint without delay You must always state the type of product the date of purchase and the serial number Otherwise the heating and plumbi...

Страница 4: ...on 17 The menu system 18 The menu system 19 The menu system 20 The menu system 21 The menu system 21 Alarms at disruption 21 Ignition phase of the burner 22 First start 22 Tuning the boiler 23 Tuning...

Страница 5: ...ons to ensure that the quality of the pellets does not deteriorate Never use pellets which do not meet European pellet standards as this may result in problems in operating the burner In general Infor...

Страница 6: ...fitted with ignition protective covering and the floor must be made of non combustible material Minimum ceiling height at the boiler is 2 metres The boiler room or boiler house must be equipped with...

Страница 7: ...r heats the water in the boiler which provides heat to the domestic and hot water The turbulators In the tubes in the convective part hangs the turbulators The turbulator s function is to reduce the h...

Страница 8: ...ons Controls and tuning of the product should be made by a proffesional A chimney sweeper should also be contacted when commisioning the product The electrical connections must be done by a profession...

Страница 9: ...a set time during fire the burner stops and goes into cooling phase Overheating protection on the boiler There is an overheating protection on the boiler which cuts the power to both the boiler and t...

Страница 10: ...measuring instruments 2 Soot door 2 Return hot water circuit 1 2 Sootdoor flue pipe 3 Handle soot door 3 Flow hot water circuit 1 3 Sootdoor 3 pc 4 Cover plate electricity 4 Hoses electrical wiring 4...

Страница 11: ...ney sweeper inspect and give advices and guidances regar ding any necessary steps needed to be taken regarding the chimney and the boilers connection to it Some issues needed to be considered Dimensio...

Страница 12: ...emperature and also cleaning the tubes when pulled up and down Cleaning system boiler Function and service Cut the power to the boiler before servicing The solenoid is mounted on the boiler to keep th...

Страница 13: ...e the settings are made The compressor The compressor creates a pressure in the container The compressor has a life span of at least 2500 hours It might then need to be serviced Effecta provides a ren...

Страница 14: ...230 VAC PE Ground N Zero 11 Radiator pump 2A 230 VAC 12 Shunt motor N Zero 13 Shunt motor 2A 230 VAC PE Ground N Zero 14 Solenoid valve AERO 2A 230 VAC PE Ground N Zero 15 Compressor 2A 230 VAC PE N...

Страница 15: ...ADIATOR PUMP OVER HEAT PROTECTION 95 C POWER GRID 230 V BL UE BR OW N YELLOW GREEN BLUE BROWN YELLOW GREEN YELLOW GREEN BROWN BLUE EXPANSION CARD EL HEATER ROOM SENS N L1 EL 2a EL 2b EL 1b EL 1a L2 L2...

Страница 16: ...ft the casing up Then connect the input voltage to the card s ports accor ding to wiring diagram on previous page ts a el och som som elen e t f r g NOTE The boiler must be filled with water before th...

Страница 17: ...pe Adjustment Energy saver 06 _ _ _ _ 22 06 _ _ _ _ 22 06 _ _ _ _ 22 06 _ _ _ _ 22 06 _ _ _ _ 22 06 _ _ _ _ 22 06 _ _ _ _ 22 Lowering temp Mon Tue Wedn Thu Fri Sat Sun 5 C Both 20 0 18 2 C 50 C Yes 60...

Страница 18: ...peration dose Fill feeder Run supp dose Supp dose Start dose Start dose size measured according to page 23 Size of support dose dose is given between ignition and running mode Size of the high effect...

Страница 19: ...Choice of external START STOP control to the boiler The control could be done either by NC or NO connection Installation Fan pre oper Clean phase out Phase out Testblow start Seconds the fan blows be...

Страница 20: ...r 3 kW Log of runtimes of the different electrical heating steps Heating off Outdoor temp when heating turns off Rad pump is runned 1min 2hours Outdoor temp Outdoor temperature at the outdoor sensor H...

Страница 21: ...ikely problem is that the pellets is out Flame sensor can also be covered by soot Alarm Ignition The burner has missed the ignition phase most likely problem is poorly adjusted starting dose Also chec...

Страница 22: ...el heater Set the temperature for the electrical heater to start if there would accure a fault or the pellet should run out Set the temperature 5 10 C below the burners start temperature Cleaning of...

Страница 23: ...increased a bit and if it smokes a lot during startup it might be decreased a bit Operation dose The operation dose is set in the menue RUN OPER DOSE Weigh the pellet that is fed through the auger an...

Страница 24: ...valve 3 Cold water 8 Vent pipe 4 Hot water out 9 Safety valve 5 Cold water in 10 Overflow pipe Hot water Hot water is produced in a copper coil There are flanges on the outside on the coil for best h...

Страница 25: ...er 5 on the main board 2 Not used 1 Connected to number 4 on the main board Shunt control In the menu shunt control there are different options of controls indoor sensor outdoor sensor or both in comb...

Страница 26: ...Energy saver function must be switched off Valves on the radiators must be fully open Radiators must be checked and in function It is normal that during the first heating season changes must be done...

Страница 27: ...Outdoor temperature Temperature flow Adjustment Slope 50 C adjustment 5 C Slope 50 C with no adjustment If it is cold outdoors cold winter and the room temperature is too low Increase the slope with...

Страница 28: ...pressed in to the drop pipe The tube should not be stretched or squashed Check inside the store that the auger intake is completely visible Adjust if necessary by loosening the clamp 2 and rotate the...

Страница 29: ...to the burner cable to the flame sensor and the air supply if its connected let the ignition element stay remain in the ignition device Note the electrical routing and attachment of all cables Discon...

Страница 30: ...house Then take the flame sensor out and replace with the new Reassemble in reverse order When cleaning the flame sensor use a damp cloth after you loosened the burner from the burner tube Overheated...

Страница 31: ...tion element cap is removed 5 and the element is pulled out of the square tube Slide the new element in the square tube Push to lie on the outer edge of the square tube 6 Install the clamp and tighten...

Страница 32: ...soot and pellet residues Reassemble in reverse order Mounting and adjusting of the draft stabiliser A draft stabiliser makes sure that a constant and stable draft is achieved Also condensation in the...

Страница 33: ...sh cleaner If you do not have access to a an ash cleaner remove the ash with a scrape and keep it in a fireproof bin Remember that ashes can contain hot particles for a long time and may not be stored...

Страница 34: ...better place Soot in the boiler room Leaking seals Contact your installer Alarm flue gas Sooty boiler Poor combustion Broken sensor Clean the boiler Contact your installer Contact your installer No he...

Страница 35: ...2011 2012 2013 2014 2015 Tillverknings r Manufacturing year Tillverkare Manufactory Hersteller Fabricants Modell Model Typ Mod le Godk nd enl Approved by Zugelassen nach Approuv Milj klass Emission c...

Страница 36: ...TER 1 2 RETURN HOT WATER 1 3 DRAIN COCK 1 2 EXPLANATIONS Width Depth incl smoke pipe Height Weight Maximum pressure Flue tube angle extra Flue tube diameter Floor to cc smoke pipe Water Volume Recomme...

Страница 37: ...v gen 21 43496 kungsbacka Tel 0300 22320 Fax 0300 22395 E post info effecta se www effecta se 010 12 13 V50 05 56 E A COMPONENTS 8 1 ROOM THERMOSTAT 2 RADIATOR VALVE 3 RADIATOR PUMP 4 REFILL 5 SHUNT W...

Страница 38: ......