8
5
Connect Foot Pedal
6
• The Ultra 1400 Series is normally
operated using the foot pedal provided.
• Connect the foot pedal to the back of the
Ultra 1400.
• If you prefer, you can also operate the
Ultra 1400 with an optional finger switch.
Specify EFD part #2015FS.
• Attach an EFD syringe barrel filled with your fluid
to the adapter assembly.
• Snap the safety clip on the adapter hose closed to
prevent dripping. Remember to unsnap the clip
when ready to dispense.
• Replace tip cap with an EFD precision dispense tip.
• Place syringe barrel in the barrel holder.
4
• Check the voltage label to be certain it is set to the available power.
The Ultra 1400 is shipped with the fuse cartridge set for 120 VAC input.
• To change the voltage, remove the voltage selector from the cartridge,
rotate it and position the correct voltage to show through the cartridge
window. Replace the cartridge into the power cord receptacle, making
sure that both sides snap securely into position.
• Connect the power cord into the
back of the Ultra 1400.
• Connect the power cord into your
local power source.
• Press the power switch on the back
panel.
Set Voltage / Connect Power
Getting
Started
Attach Syringe Barrel / Dispense Tip
spare fuse
voltage value
cartridge window
foot pedal
connector