EFA M-VBE 6 Скачать руководство пользователя страница 9

Mobile   animal   stunning   device   VBE-M   

 

 

 

9   

 

7.2   Main   controller   parameters   that   can   be   reprogrammed   

 

 

 

 

 

Parameter   available   after   entering   the   programming   mode   

 

 

 

Cd   -     

access   code 

,   allows   access   to   other   parameters    

  

General   parameters   

 

 

 

Lc   -   allows   setting   the   access   code:    

  

0    

-   no   access   code   (all   other   parameters   are   visible   without   entering   the   access   code);  

any   value   other   than    

 activates   the    

Cd 

 parameter   (entering   the   other   parameters   will   be  

 

 

 

   

 

 

 

 

 

 

 

 

 

 

possible   after   entering   this   value);   

 

5  

  -   factory   set   access   code.   

 

 

 

tSG   -   does   not   apply   to     VBE-M   

 

 

 

YEAr   -   setting   the   date   (year)   

 

 

 

Mon   -   setting   the   date   (month)   

 

 

 

dAY   -   setting   the   date   (day)   

 

 

 

Hour   -   setting   the   time   (hours)   

 

 

 

Min   -   setting   the   time   (minutes)   

 

 

 

SEc   -   setting   the   time   (seconds)   

 

 

 

toFH   [s]   -   does   not   apply   to     VBE-M   

 

 

 

Pr   -   allows   to   select   the   stunning   program   

 

Parameters   of   the   selected   stunning   program   

 

 

 

toFF  [s]  -  pause  between  subsequent  stuns  (delay  time  between  the  stunning  current  decay  and  the  

 

   

 

 

 

 

 

 

 

 

 

 

 

 

 

end   of   the   stunning   process   

 

 

 

dL1   [s]   -    

phase   1  

  -   duration   of   stunning   phase   1   (cannot   be   shorter   than   1.0   s) 

 

 

 

 

Fr1b   [Hz]    -   initial   frequency   of   stunning   phase   1   

 

 

 

Fr1E  [Hz]  -  end  frequency  of  stunning  phase  1.  The  frequency  changes  from  Fr1b  to  Fr1E  over  the  

 

   

 

   

 

   

 

 

 

 

   

 

 

 

duration   of   dL1   

 

 

 

SP1b   [A]    -   initial   current   of   stunning   phase   1   

 

Содержание M-VBE 6

Страница 1: ...MOBILE ANIMAL STUNNING DEVICE VBE M MAULBRONN 1ST EDITION MAY 2021 Index number ________M0056 M Software version ____________E5 5 Serial number _____ ____ _____...

Страница 2: ...BE M CAUTION The device meets the requirements of Council Regulation EC No 1099 2009 of 24 September 2009 on the protection of animals at the time of killing Regulation 1099 2009 FSIS Directive 6900 2...

Страница 3: ...ng 18 10 2 Parameter reading 18 DOWNLOADING AND UPLOADING STUNNING PARAMETERS 19 11 1 Uploading parameters to the device from the SDHC card 19 11 2 Downloading parameters from the device to the SDHC c...

Страница 4: ...to touch the electrodes CAUTION Wires and sockets of the device must not be exposed to water The inspection window of the device should always be tightly closed After finishing work it is absolutely...

Страница 5: ...from accessing the device CAUTION Residual risk occurs in case of failure to comply with recommendations and guidelines listed above 3 CONTENTS OF THE SDHC CARD On the SDHC card of the device there ar...

Страница 6: ...ronic equipment Do not connect the device to the mains if the connection or socket is damaged Do not wash with pressure washers Fig 2 Signal lights yellow light END OF STUNNING red light STUNNING gree...

Страница 7: ...readiness for operation mode the device has been properly turned on and is ready for use stunning mode the device measures the animal s resistance starts the stunning process and maintains the set pa...

Страница 8: ...define new stunning programs set current date and time Fig 4 Control panel Buttons selecting between parameters parameter values enter confirm escape exit switching the stunning program changing the...

Страница 9: ...es not apply to VBE M YEAr setting the date year Mon setting the date month dAY setting the date day Hour setting the time hours Min setting the time minutes SEc setting the time seconds toFH s does n...

Страница 10: ...f stunning phase 3 Setting dL3 to 0 cancels this phase The following parameters will then disappear from the menu Fr3b Fr3E SP3b SP3E tP3 Fr3b Hz initial frequency of stunning phase 3 The frequency ju...

Страница 11: ...nning after the transition phase 12 head heart sinusoidal waveform suspension of stunning after the transition phase 13 head heart rectangular waveform suspension of stunning after the transition phas...

Страница 12: ...over the device suspends the stunning the measuring voltage appears on the electrodes after removing the electrodes from the animal s head the device goes into the standby mode when the green light tu...

Страница 13: ...tery is discharged to more than 50 Then you should stop stunning and connect the device to the mains in order to charge the battery During the stunning process the battery voltage will drop Battery ch...

Страница 14: ...power system 5 Fig 7 pos 4 the light indicating the battery charging is on steady red light battery charging flashing red green light battery charged recharging in the range of 500 900 mA steady green...

Страница 15: ...the stunning process continues until the electrodes are removed from the animal s head or until the sum of phase durations is complete The end of the process will be signaled by the red light STUNNING...

Страница 16: ...show the stunning current display C will show the duration s counted from the beginning of the stunning process display V will show the stunning voltage 5 After reaching the stunning duration SPt or...

Страница 17: ...select the program to be modified 3 Confirm by pressing the value on display V starts blinking 4 Using the buttons select the program to be modified 5 Confirm by pressing the letters on display A C st...

Страница 18: ...mat average voltage V measured during the stunning process maximum current A measured during the stunning process electric charge C measured during the stunning process duration of the stunning proces...

Страница 19: ...subsection 11 1 To download your own parameter settings from the device to SDHC card e g to transfer them to another device follow steps listed in subsection 11 2 11 1 Uploading parameters to the dev...

Страница 20: ...BDrv directory EFA software for VBE M PC communication PC directory Directories with installation files are in the main directory of the SDHC card see section 3 12 1 Installation of the USB converter...

Страница 21: ...e is ready for use Clicking on the notification will open a window with information on which COM port has been assigned to the converter If the notification does not appear the created COM port can be...

Страница 22: ...ice VBE M 22 12 2 Installation of the EFA software for VBE M PC communication STEP 1 Open the PC Installer folder and run setup exe STEP 2 Follow the on screen instructions 1 2 Do not change the defau...

Страница 23: ...ching the program for VBE M PC communication STEP 3 Restart the computer STEP 4 Create a config folder directly on drive C 5 STEP 1 Before turning on the VBE M connect the USB converter to the USB por...

Страница 24: ...or VBE M PC communication STEP 1 Go to the CONFIGURATION tab enter 129 in the CODE field and confirm by pressing Enter code 129 unlocks all parameters available for editing STEP 2 Set the READING STZ...

Страница 25: ...L PORT NO STEP 4 Create a folder for saving logs from stunning CAUTION If the USB converter is connected to a different USB socket on the PC the COM port number will change 1 Press the directory butto...

Страница 26: ...m as administrator see section 12 3 STEP 2 If the configuration was successful COMMUNICATION ERROR has changed to COMMUNICATION OK This means that the device and program have been set up correctly and...

Страница 27: ...ror message appears it means that the stz folder has not been properly created and needs to be re created see section 12 4 STEP 4 VIEW tab After each stunning process another entry is added to the stu...

Страница 28: ...toring of the technical condition of individual assemblies and parts that impact work safety Periodic maintenance determining the technical condition of the device determining the degree of wear of in...

Страница 29: ...ect disposal of the device may contribute to reducing the negative impact on the natural environment and human health the device must be disposed of in accordance with local regulations regarding the...

Страница 30: ...is turned off Turn the device on with the START button on the main switch START STOP Fig 2 No stunning process The electronics do not work The displays do not work Check the fuse or report the fault t...

Страница 31: ...evice is recyclable It is subject to the selective collection of electrical and electronic equipment EFA Schmid Wezel GmbH Maybachstra e 2 75433 Maulbronn www efa germany com Phone 49 0 7043 102 0 Fax...

Отзывы: