Mobile animal stunning device VBE-M
9
7.2 Main controller parameters that can be reprogrammed
Parameter available after entering the programming mode
Cd -
access code
, allows access to other parameters
General parameters
Lc - allows setting the access code:
●
0
- no access code (all other parameters are visible without entering the access code);
●
any value other than
0
activates the
Cd
parameter (entering the other parameters will be
possible after entering this value);
●
5
- factory set access code.
tSG - does not apply to VBE-M
YEAr - setting the date (year)
Mon - setting the date (month)
dAY - setting the date (day)
Hour - setting the time (hours)
Min - setting the time (minutes)
SEc - setting the time (seconds)
toFH [s] - does not apply to VBE-M
Pr - allows to select the stunning program
Parameters of the selected stunning program
toFF [s] - pause between subsequent stuns (delay time between the stunning current decay and the
end of the stunning process
dL1 [s] -
phase 1
- duration of stunning phase 1 (cannot be shorter than 1.0 s)
Fr1b [Hz] - initial frequency of stunning phase 1
Fr1E [Hz] - end frequency of stunning phase 1. The frequency changes from Fr1b to Fr1E over the
duration of dL1
SP1b [A] - initial current of stunning phase 1