Mobile animal stunning device VBE-M
15
The
length of the stunning process
is determined by the parameters:
●
SPt
-
stunning duration
- the time after which the alarm signaling the end of the stunning process is
activated - the electrodes can be removed from the animal's head;
●
dL1
+
dL2
+
dL3
-
sum of phase durations
;
If the
sum of phase durations
is greater than the
stunning duration
(
SPt
), the stunning process
continues until the electrodes are removed from the animal's head or the
sum of phase durations
ends - see:
Diagram 1
.
CONTINUOUS MODE - head :
Before starting the stunning process, only the measuring voltage occurs on the electrodes.
1. After pressing the electrodes to the animal’s head the device will enter the
stunning mode
. The
stunning process will start automatically:
The control system will give stunning voltage – the red light (STUNNING) will turn on:
● display
[A]
will show the stunning current;
● display
[C]
will show the duration [s] counted from the beginning of the stunning process;
● display
[V]
will show the stunning voltage.
2. After reaching the
stunning duration
(
SPt
) or the
sum of phase durations
the yellow light
(END OF STUNNING) and the sound alarm will turn on - see:
Diagram 1
:
Remove the electrodes from the animal’s head
After reaching the
stunning duration
(
SPt
), the stunning process continues until the
electrodes are removed from the animal's head or until the
sum of phase durations
is
complete.
The end of the process will be signaled by the red light (STUNNING) turning off.
2. After removing the electrodes:
●
the red light (STUNNING) and the yellow light (END OF STUNNING) will turn off;
●
the sound alarm will turn off;
●
display
[A]
will show
0
(no stunning current);
●
display
[C]
will show the duration of last stunning process
●
display
[V]
will show the measuring voltage on the electrodes.
3. After reaching the value set in the
toFF
parameter (pause between stunning) the device is in
readiness for operation mode
again.
TWO-STAGE MODE - head-heart:
In the
head-heart
mode, one of the first stunning phases (
dL1
or
dL2
) should be set as the
transition phase
- see:
Diagram 2
and
3
.
Before starting the stunning process, only the measuring voltage occurs on the electrodes.
1. After pressing the electrodes to the animal’s head the device will enter the
stunning mode
. The
stunning
STAGE I
(head) will start automatically:
The control system will give stunning voltage – the red light (STUNNING) will turn on:
● display
[A]
will show the stunning current;
● display
[C]
will show the duration [s] counted from the beginning of the stunning process;
● display
[V]
will show the stunning voltage
.
2. After the end of the
transition phase
(
dL1
or
dL2
), the device will signal the end of the
stunning
STAGE I
(head) - the yellow light (END OF STUNNING) and the sound alarm will turn
on.