3) ELECTRICAL HOOK-UP

Your Eemax heater must have its own independent circuit using

insulated, UL listed, 3 wire cable of the appropriate size suitable 

for use up to 75 

o

C protected by the correctly rated circuit breaker. 

RATINGS OF “SP” UNITS

WARNING

BEFORE BEGINNING ANY WORK ON THE INSTALLATION

BE SURE THAT THE BREAKER IS “OFF”

TO AVOID ANY DANGER OF SHOCK.

FIGURE 2

OUTLET VALVE (B)

(ADJUST TO GIVE

APPROXIMATE

DESIRED TEMP.)

MODEL

VOLTS

kW

AMPS

0.5 gpm

0.6 gpm 0.7 gpm

SP2412

120

2.4

20

33

-

-

SP3012

120

3.0

25

41

34

29

SP3512

120

3.5

29.2

48

40

34

SP3208

208

3.0

14.4

41

34

29

SP4208

208

4.1

19.7

56

47

40

SP8208

208

8.3

40

-

-

81

SP3277

277

3.0

10.8

41

34

29

SP4277

277

4.1

14.8

56

47

40

SP60

277

6.0

22

-

68

58

TO APPROPRIATE
SIZE BREAKER

WIRE ENTRY
EITHER THROUGH
REAR OR
BOTTOM 
KNOCK-OUTS

INLET VALVE(A)

(FULLY OPEN)

* The heaters are rated at 240 Volts. If the actual voltage supplied is lower

(220, 208V) there will be a proportional drop in output.

1) Wire entry into the unit should be made through the lower right hand corner of
the backplate via one of the two “knockout” holes provided.

2) The “mains” wires should be connected to the slots in the terminal block marked
L1 and L2 or N. The ground lead 

MUST

be connected to the marked. 

Failure to ground the system may result in death or serious injury.

WARNING:

This water heater must not be switched “on” if there is

possibility

that the water in the heater is frozen.

SP60

277

6.0

22

-

68

58

SP80

277

8.0

29

-

-

78

SP90

277

9.0

33

-

-

88

SP100

277

10.0

36

-

-

97

SP35

240*

3.5

14.6

48

40

34

SP55

240*

5.5

22.9

75

63

54

SP65

240*

6.5

27

-

73

63

SP75

240*

7.5

32

-

-

73

SP95

240*

9.5

40

-

-

92

MOUNTING HOLES

1/4

inches

8 inches

APPROPRIATE
GAUGE  COPPER

WIRE (2 conductors 

1 ground)

INSTALL

THIS WAY UP

ONLY !

UP

relay

ECO – RE-SETABLE HIGH 
TEMPERATURE CUT-OUT

Содержание Single Point Series

Страница 1: ...ATSOEVER THE MANUFACTURER OF THIS HEATER WILL NOT BE LIABLE FOR ANY DAMAGES BECAUSE OF FAILURE TO COMPLY WITH THE INSTALLATION AND OPERATING INSTRUCTIONS OUTLINED ON THE FOLLOWING PAGES Eemax Inc 353 Christian Street Oxford CT 06478 THE INSTALLATION MUST CONFORM WITH THE INSTRUCTIONS IN THIS MANUAL AND LOCAL CODES OR INTHE ABSENCE OF LOCAL CODES WITH THE LATEST EDITION OF THE NATIONAL ELECTRICAL C...

Страница 2: ...plastic piping Do not use additional screwed fittings or pipe dope Doing so will void the warranty DO NOT SOLDER PIPES WHILE THE UNIT IS INSTALLED DO NOT USE PIPE DOPE OR TEFLON TAPE serious damage to the electronic flow switch will result position WILL cause element burn out 3 The cold water inlet is on the right hand side and the hot water outlet is on the left hand side Under NO circumstances c...

Страница 3: ...ucet on and off repeatedly 3 Switch on electric supply at breaker 4 The power indicator light should now come on see Fig 1 NOTE At this point water temperature may not be very hot 5 Using the OUTLET BALL VALVE slowly reduce water flow until desired temperature is achieved at hot water outlet NOTE The water temperature is proportional to the flow through the heater until the water flow is continuou...

Страница 4: ... OUTS INLET VALVE A FULLY OPEN The heaters are rated at 240 Volts If the actual voltage supplied is lower 220 208V there will be a proportional drop in output 1 Wire entry into the unit should be made through the lower right hand corner of the backplate via one of the two knockout holes provided 2 The mains wires should be connected to the slots in the terminal block marked L1 and L2 or N The grou...

Отзывы: