3) ELECTRICAL HOOK-UP
Your Eemax heater must have its own independent circuit using
insulated, UL listed, 3 wire cable of the appropriate size suitable
for use up to 75
o
C protected by the correctly rated circuit breaker.
RATINGS OF “SP” UNITS
WARNING
BEFORE BEGINNING ANY WORK ON THE INSTALLATION
BE SURE THAT THE BREAKER IS “OFF”
TO AVOID ANY DANGER OF SHOCK.
FIGURE 2
OUTLET VALVE (B)
(ADJUST TO GIVE
APPROXIMATE
DESIRED TEMP.)
MODEL
VOLTS
kW
AMPS
0.5 gpm
0.6 gpm 0.7 gpm
SP2412
120
2.4
20
33
-
-
SP3012
120
3.0
25
41
34
29
SP3512
120
3.5
29.2
48
40
34
SP3208
208
3.0
14.4
41
34
29
SP4208
208
4.1
19.7
56
47
40
SP8208
208
8.3
40
-
-
81
SP3277
277
3.0
10.8
41
34
29
SP4277
277
4.1
14.8
56
47
40
SP60
277
6.0
22
-
68
58
TO APPROPRIATE
SIZE BREAKER
WIRE ENTRY
EITHER THROUGH
REAR OR
BOTTOM
KNOCK-OUTS
INLET VALVE(A)
(FULLY OPEN)
* The heaters are rated at 240 Volts. If the actual voltage supplied is lower
(220, 208V) there will be a proportional drop in output.
1) Wire entry into the unit should be made through the lower right hand corner of
the backplate via one of the two “knockout” holes provided.
2) The “mains” wires should be connected to the slots in the terminal block marked
L1 and L2 or N. The ground lead
MUST
be connected to the marked.
Failure to ground the system may result in death or serious injury.
WARNING:
This water heater must not be switched “on” if there is
a
possibility
that the water in the heater is frozen.
SP60
277
6.0
22
-
68
58
SP80
277
8.0
29
-
-
78
SP90
277
9.0
33
-
-
88
SP100
277
10.0
36
-
-
97
SP35
240*
3.5
14.6
48
40
34
SP55
240*
5.5
22.9
75
63
54
SP65
240*
6.5
27
-
73
63
SP75
240*
7.5
32
-
-
73
SP95
240*
9.5
40
-
-
92
MOUNTING HOLES
4
1/4
inches
8 inches
APPROPRIATE
GAUGE COPPER
WIRE (2 conductors
1 ground)
INSTALL
THIS WAY UP
ONLY !
UP
relay
ECO – RE-SETABLE HIGH
TEMPERATURE CUT-OUT