I.  MOUNTING THE UNIT

1) The unit should be mounted as close to the point of use as possible.

Do not 

install the heater above a faucet or “point of use” because the siphoning effect may  

drain the heater which can cause premature element burn out.  If the unit must be installed at      
a higher elevation, you must install spring loaded check valves on both the inlet and outlet of 
the water heater.

2) This unit must only be mounted in a vertical position with the 

water fittings positioned at

the bottom of the unit

. Mounting other than in the vertical position 

will

cause element burn 

out and permanent damage to the water heater.

3) The cold water inlet is on the right hand side and the hot water outlet is on the left hand side

as marked by the fittings of the unit.  Under 

NO

circumstances can these be reversed.

4) Leave a minimum of 8” above the unit for easy replacement of the element.

5) The heater should be fixed to the wall using

all 

four mounting holes of the backplate. (Fig.1)

Use an appropriate fastener for the weight.  For the unit to be mounted against hollow walls,
we suggest using steel wall anchors with the correct grip range, and #10-32 screws at a 

minimum.

NOTE: The heater should be installed 

below

the level of all hot water outlets serviced by this

heater.  Otherwise install spring loaded check valves on both the inlet and outlet.

NOTE: PRESSURE AND TEMPERATURE RELIEF VALVE

These units are not required by UL to have a Pressure and Temperature Relief
Valve (PTRV). You should check with local codes to find out if one is required in your
area.  If local codes require the use of a temperature and pressure relief valve it
should be installed on the outlet hot water pipe before the outlet ball valve.

3

Requirements

:

Max Output:  3.5 kW    @ 120 volts

8.3 KW   @ 208 volts
11.5 kW  @ 240 volts
10.0 kW  @ 277 volts

About 0.7 - 2.5 GPM at showering temperature.

MODELS:

1

Φ 120V:

PA004120T

1Φ 208V:

PA008208T

1

Φ 240V:

PA005240T, PA007240T, 
PA010240T, PA012240T

1

Φ 277V:

PA008277T, PA010277T

Eemax

Lavatory

Shower

Kitchen

Hot outlet

Cold inlet

Содержание ProAdvantage PA004120T

Страница 1: ...E TO FOLLOW THE SAFETY RULES MAY CAUSE THE UNIT TO OPERATE IMPROPERLY WHICH COULD LEAD TO DEATH SERIOUS BODILY INJURY AND OR PROPERTY DAMAGE READ THE ENCLOSED WARRANTY CARD WARRANTY OF THIS WATER HEATER WILL DEPEND ON PROPER INSTALLATION AND OPERATION THE WARRANTY SHALL BE VOID IF THE DESIGN HAS BEEN ALTERED THE MANUFACTURER OF THIS HEATER WILL NOT BE LIABLE FOR ANY DAMAGES BECAUSE OF FAILURE TO C...

Страница 2: ...R FURTHER INFORMATION FAILURE TO GROUND THE SYSTEM MAY RESULT IN DEATH OR SERIOUS INJURY WARNING WARNING WATER HEATERS ARE EQUIPPED FOR ONE VOLTAGE ONLY THIS WATER HEATER IS EQUIPPED FOR THE VOLTAGE DISPLAYED ON THE MODEL RATING PLATE DO NOT USE THIS WATER HEATER WITH ANY OTHER VOLTAGE OTHER THAN THE ONE SHOWN ON THE MODEL RATING PLATE FAILURE TO COMPLY WITH THIS MAY RESULT IN DEATH SERIOUS BODILY...

Страница 3: ...d to the wall using all four mounting holes of the backplate Fig 1 Use an appropriate fastener for the weight For the unit to be mounted against hollow walls we suggest using steel wall anchors with the correct grip range and 10 32 screws at a minimum NOTE The heater should be installed below the level of all hot water outlets serviced by this heater Otherwise install spring loaded check valves on...

Страница 4: ...Mounting Layout for Series 1 Systems 4 Fig 1 ...

Страница 5: ...ow switch 4 Install isolating valves full flow ball valve type on both inlet and outlet pipes This allows unit to be isolated for maintenance purposes Fig 2b 5 When all plumbing is complete fully check the system for water leaks at all the plumbing connections If any leaks are present take corrective action Then fully open both inlet and outlet BALL VALVES run the hot water outlet fed by this heat...

Страница 6: ...re correctly aligned with the inlet and outlet bosses in order to avoid excessive stress on the heater body molding 6 Inlet Isolating Ball Valve Always leave fully open when unit is in service Outlet Isolating Ball Valve throttle open just enough to obtain adequate flow of hot water Union Threaded type Teflon tape only No pipe dope NPT Elbow s Pipe support Figure 2b Pipe support L1 GND N L2 or Con...

Страница 7: ...L Use a dedicated circuit with appropriate wiring and circuit breaker configuration which is dictated by the power requirements of the unit see Table 1 and Fig 3 DANGER FAILURE TO GROUND THE SYSTEM MAY RESULT IN DEATH OR SERIOUS INJURY MODEL TYPE Voltage kW output AMPERAGE PA004120T 1f 120V 3 5 29 PA008208T 1f 208V 8 3 40 PA005240T 1f 240V 4 8 20 PA007240T 1f 240V 6 5 27 PA010240T 1f 240V 9 5 40 P...

Страница 8: ...effects One any air in the system will be purged out Two the heater unit will be pressurized up to the supply pressure This will prevent the elements from having air pockets when energized 4 At this point you may energize the hot water heater Once energized the Thermostatic control touch pad display on the front cover will illuminate This is where and when you will program your desired temperature...

Страница 9: ...e hot water outlet left side 4 ELEMENT BURNED OUT TURN OFF THE MAIN CIRCUIT BREAKER Using an ohmmeter test the resistance of the heating element across the two threaded termination rods on top of the element The resistance reading should be 4 15 ohms If the resistance is much greater than this value call Eemax for a replacement element SYMPTOM B LOW OR NO HEAT INDICATOR LIGHT ON 1 WATER FLOW TOO H...

Страница 10: ...ORE TRIAC CONTACTOR Figure 6 Figure 7 10 RELAY ORG TO RELAY COIL T C BLU 2 PIN CONNECTOR 6 Wire T C EX 284 EL L BLK ELEMENT RING TRIAC BLK RELAY ORG TO ECO L1 POWER BLK FROM RELAY LINE SIDE L2 N POWER RE FROM RELAY LINE SIDE Figure 8 ...

Отзывы: