2) PLUMBING HOOK-UP 

The heater is supplied with brass 3/8” compression fittings that are compatible with either stainless steel flex 
hose, copper or plastic pipe. Make sure these fittings are used for this installation. Contact your Eemax 
representative for further information.  

Eemax strongly recommends that the heater be supplied directly from the main cold water line when possible. 
This helps to avoid a potential water flow interruption to the heater which could lead to a failure of the heating 
element. 

Minimum working pressure of 30psi. 

Maximum Operating System Pressure of – 150 psi. 

Optimum Operating Pressure 35 - 80 PSI (Anything over 80 PSI must have pressure reducing regulator). 

For optimum performance, we recommend the use of isolation valves (full flow ball type) on the inlet and outlet 
pipes. 

BEFORE ATTEMPTING ANY INSTALLATION, MODIFICATION OR SERVICE OF THIS HEATER, 
MAKE SURE THE ELECTRICAL POWER IS DISCONNECTED. 

 

NEVER SUBSTITUTE THREADED PIPE FITTINGS USING PIPE DOPE OR TEFLON TAPE AND 
NEVER SOLDER ANY PIPE CONNECTIONS WHILE ATTACHED TO THIS HEATER BECAUSE 

DAMAGE TO THE HEATER WILL RESULT. DOING THIS WILL VOID THE WARRANTY! 

1.

 The heater’s water INLET and OUTLET are labeled. Install 

full  flow  ball  valves  to  the  inlet  and  outlet  pipes  and  run 
water through the inlet pipe into a bucket to purge it of any 
debris. Close the inlet ball valve. 

 

2.

  Make  sure  the  inlet  filter  screen  is  present  in  the  inlet 

fitting  and  the  inlet  and  outlet  pipes  are  correctly  aligned 
with  the  heater  connections  to  minimize  stress  on  the 
heater. 

 

Содержание LavAdvantage

Страница 1: ...INSTALLATION GUIDE AND OWNER S MANUAL LavAdvantage ELECTRIC INSTANTANEOUS WATER HEATERS ...

Страница 2: ...lable through your local authorities You must understand these requirements before beginning this installation This unit is not required by UL 499 to have a Temperature and Pressure relief valve T P You should check with local codes to find out if one is required If it is it must be installed in the outlet hot water pipe between the heater and the isolation valve IMPORTANT SAFETY INSTRUCTIONS When...

Страница 3: ...ONDUCTEURS DE MIZE À LA MASSE CONFORMEMENT AU CODE CANADIEN DE L ÉLECTRICITÉ PARTIE I SAVE THESE INSTRUCTIONS GENERAL The Eemax LavAdvantage heaters will provide optimum performance and energy savings when located under the sink and as close as possible to the point of hot water use For best performance the heater should be BELOW the point of use Failure to do so may void the warranty Contact your...

Страница 4: ...nder the sink as close to the point of use as possible Ideal position is fittings pointed down but the heater can be mounted in any orientation 2 Make sure to leave a minimum of 8 inches service clearance at the end OPPOSITE the fittings 3 Remove the cover and fasten to the wall using the four mounting holes at each corner of the back plate Replace the cover ...

Страница 5: ...educing regulator For optimum performance we recommend the use of isolation valves full flow ball type on the inlet and outlet pipes BEFORE ATTEMPTING ANY INSTALLATION MODIFICATION OR SERVICE OF THIS HEATER MAKE SURE THE ELECTRICAL POWER IS DISCONNECTED NEVER SUBSTITUTE THREADED PIPE FITTINGS USING PIPE DOPE OR TEFLON TAPE AND NEVER SOLDER ANY PIPE CONNECTIONS WHILE ATTACHED TO THIS HEATER BECAUSE...

Страница 6: ...ockets Close the faucet and install the aerator if supplied Failure to install aerator if supplied will result in lower than expected heater performance Model of Aerators Model of Aerators SPEX3512T ML 2 SPEX3208T ML 2 SPEX35T ML 2 SPEX4208T ML 2 SPEX48T ML 2 SPEX3277T ML 2 SPEX55T ML 2 SPEX4277T ML 2 SPEX65T ML 2 SPEX60T ML 2 SPEX75T ML 2 SPEX80T ML 2 SPEX95T ML 3 SPEX90T ML 3 SPEX012240T ML 3 SP...

Страница 7: ...SPEX48T 240 4 8 20 14 SPEX55T 240 5 5 23 12 SPEX65T 240 6 5 27 12 SPEX75T 240 7 5 32 10 SPEX95T 240 9 5 40 8 SPEX012240T 240 11 5 48 6 SPEX3208T 208 3 15 14 SPEX4208T 208 4 1 20 14 SPEX8208T 208 8 3 40 8 SPEX3277T 277 3 11 14 SPEX4277T 277 4 1 14 8 14 SPEX60T 277 6 22 14 SPEX80T 277 8 29 12 SPEX90T 277 9 33 10 SPEX100T 277 10 36 10 BEFORE BEGINNING ANY WORK ON THIS INSTALLATION BE SURE THAT THE EL...

Страница 8: ...HE HEATER IS FROZEN 1 Make sure water is flowing through the faucet 2 Switch ON the electric power supply at the breaker 2 The power leads are to be secured to the L1 and L2 or L and N connectors on the terminal block or relay The ground lead is to be secured to the GND connector on the block or the green ground wire with the provided wire nut FAILURE TO GROUND THE SYSTEM MAY RESULT IN SERIOUS INJ...

Страница 9: ...ssed Congratulations Your Eemax tankless electric water heater is fully installed and ready for use MAXIMUM TEMPERATURE RISE AT SPECIFIED FLOW RATE F GPM Model 0 35 0 5 1 1 5 2 2 5 3 SPEX1812T 35 25 12 8 6 5 4 SPEX2412T 47 33 16 11 8 7 5 SPEX3012T 59 41 20 14 10 8 7 SPEX3512T 68 48 24 16 12 10 8 SPEX35T 68 48 24 16 12 10 8 SPEX48T 66 33 22 16 13 11 SPEX55T 75 38 25 19 15 13 SPEX65T 89 44 30 22 18 ...

Страница 10: ...G TEMPERATURE To INCREASE temperature tap the button repeatedly or hold the down to INCREASE the temperature quickly To DECREASE temperature tap the button repeatedly or hold the down to DECREASE the temperature quickly ADVANCED FUNCTIONS To access the ADVANCED FUNCTIONS menu With the display showing the current setpoint temperature press BOTH AND buttons simultaneously for 3 seconds and the displ...

Страница 11: ... Menu press and hold the and buttons for 10 seconds CURRENT ERROR will display F0 displays if no errors Press the button for 1 second to cycle through the following screens CURRENT ERROR PAST ERRORS Tap the button to cycle through the past 5 previous errors F0 displays if no errors UNITS Tap the button to cycle between F GPM and C LPM To return to setpoint hold and for 10 seconds or just let the h...

Страница 12: ...12 ...

Страница 13: ...fault clear F36 Undervoltage voltage too low compared to the specified value unit keeps functioning while displaying the warning message causing condition disappears F38 High flow flow is too high for the unit to be able to keep up with heating water to setpoint temperature Fault code displayed unit continues to operate reduce flow below maximum limit for the current heater parameters F47 Inlet th...

Страница 14: ...ut off ECO Control board Contactor ELEMENT CARTRIDGE pictured below INSTALLS INSIDE HEATING CHAMBER PART NUMBERS FOR FITTINGS AERATORS AND AERATOR ADAPTORS COMPRESSION FITTINGS AERATORS 3 8 NUT EX68B 0 35 GPM EX0061 0 3 AER 3 8 SLEEVE EX68C MALE 13 16 27 X MALE 55 64 27 EX61 339 FEMALE 3 4 27 X MALE 55 64 27 EX61 341 FEMALE 13 16 24 X MALE 55 64 27 EX61 349 MALE 15 16 27 X MALE 55 64 27 EX61 336 M...

Страница 15: ... EX384 240 EX255B EX278A SPEX95T EX630 EX384 240 EX255B EX278A SPEX012240T EX500 PRT EX384 240 EX1050 1 EX278A SPEX3277T EX260 EX384 277 EX253B EX278A SPEX4277T EX1870 EX384 277 EX253B EX278A SPEX60T EX1280 EX384 277 EX253B EX278A SPEX80T EX960 EX384 277 EX253B EX278A SPEX90T EX850 EX384 277 EX253B EX278A SPEX100T EX760 EX384 277 EX253B EX278A If heater has suffix DI order element with suffix SS I...

Страница 16: ...16 Notes Eemax Inc 400 Captain Neville Drive Waterbury CT 06705 Tel 800 543 6163 203 267 7890 Fax 203 267 7975 email support eemaxinc com EX07200 81 Rev A ...

Отзывы: