(CANADIAN INSTALLATIONS ONLY) CONNECT ONLY TO A CIRCUIT PROTECTED BY A
CLASS A GROUND FAULT CIRCUIT INTERRUPTER. ATTENTION: BRANCHER UNIQUEMENT
À UN CIRCUIT PROTÉGÉ PAR UN DISJONCTEUR DE FUITE DE TERRE DE CLASSE A.
(CANADIAN INSTALLATIONS ONLY) DO NOT INSTALL IN A BATH ENCLOSURE OR
SHOWER STALL OR CONNECT TO A SALT-REGENERATED WATER SOFTENER OR A
WATER SUPPLY OF SALT WATER. ATTENTION: NE PAS INSTALLER DANS UNE BAIGNOIRE OU UNE CABINE DE
DOUCHE ET NE PAS BRANCHER À UN ADOUCISSEUR D’EAU RÉGÉNÉRÉ AVEC DU SEL OU À UN
APPROVISIONNEMENT EN EAU SALÉE.
(CANADIAN INSTALLATIONS ONLY) USE COPPER CONDUCTORS ONLY. USE BONDING
CONDUCTOR IN ACCORDANCE WITH THE CANADIAN ELECTRICAL CODE PART I. UTILISEZ
DEZ CONDUCTEURS EN CUIVE UNIQUEMENT. UTILISEZ DES CONDUCTEURS DE MIZE À LA MASSE
CONFORMEMENT AU CODE CANADIEN DE L’ÉLECTRICITÉ, PARTIE I.
SAVE THESE INSTRUCTIONS
GENERAL
The Eemax, Inc.™
LavAdvantage
heaters will provide optimum performance and energy savings when located
under the sink and as close as possible to the point of hot water use. For best performance, the heater should be
BELOW
the point-of-use. Failure to do so may void the warranty. Contact your Eemax representative for further
information.
LavAdvantage
heaters accept cold or preheated water and heat it to temperatures suitable for normal domestic
usage up to a maximum temperature setpoint of 140°F. Models featuring the “S” option can be used as a
temperature booster for sanitation applications up to maximum temperature setpoint of 180°F. “ML” option
units are factory set to a maximum temperature setpoint of 110°F and are recommended for multi-lavatory
handwashing applications – refer to section 2 for supplied aerator details. The “EE” option units are factory set
to a maximum temperature setpoint of 90°F, making them suitable for emergency eyewash applications.
To obtain optimum performance and energy savings, the unit should be located as close as possible to the point-
of-use. The unit is supplied with compression rings and nuts suitable for direct coupling to 3/8” copper or PEX™
piping. Do not use additional screwed fittings, pipe dope or teflon tape – doing so will void the warranty.
DO
NOT SOLDER PIPES WHILE THE UNIT IS INSTALLED
as serious damage to the heater will result and the warranty
will be voided.