4-­‐   PLUMBING   INSTALLATION   

Please   follow   all   plumbing   instructions   carefully.   We   recommend   that   this   product   be   installed   by   a   licensed   and   
qualified   plumber   in   accordance   with   all   applicable   national,   state,   provincial,   and   local   plumbing   codes.   

Installation   Instructions   

STEP   1:

   Connect   the   HOT   WATER   line   to   the   water   heater   OUTLET   located   on   the   left   when   facing   unit.   Connect   

the   COLD   WATER   line   to   the   water   heater   INLET   located   on   the   right   when   facing   unit.   

STEP   2:

   After   tightening   both   fittings   on   the   water   heater,   open   several   hot   water   faucets   and   allow   water   to   run   

though   the   water   heater   for   at   least   2   to   3   minutes.   This   process   purges   all   the   air   from   the   water   lines   and   
MUST   be   performed   prior   to   turning   on   the   power   at   the   unit.   FAILURE   TO   FOLLOW   THIS   STEP   CAN   CAUSE   
PERMANENT   DAMAGE   TO   THE   HEATING   ELEMENTS.   If   any   maintenance   is   performed   on   the   water   heater   or   the   
home’s   plumbing   system   that   may   introduce   air   into   the   plumbing   pipes,   it   is   important   to   turn   the   power   off   to   
the   water   heater   and   purge   the   air   out   of   the   lines   before   allowing   the   unit   to   power   up.   

STEP   3:

   Carefully   inspect   all   connections,   unions,   and   the   pressure   relief   valve   (if   installed)   for   leaks.   

IMPORTANT   NOTES:   

1.

  

Do   not   solder   any   pipes   with   unit   connected   to   pipes   –   heat   from   soldering   may   damage   the   flow   
sensor.   Doing   so   will   void   the   warranty.   
   

2.

  

This   automatic   tankless   water   heater   is   equipped   with   both   computer-­‐controlled   and   electro-­‐
mechanical   auto   resetting   thermostat   switches   for   high-­‐limited   temperature   protection.   Since   this   
product   does   not   use   a   storage   tank,   the   use   of   a   temperature   pressure   relief   valve   (T&P)   is   not   required   
for   most   installations.   UL   Standard   499   does   NOT   require   that   a   pressure   relief   valve   be   used.   However,   
a   T&P   valve   may   be   required   to   meet   installation   codes   in   your   area.   If   one   is   required,   install   the   
pressure   relief   valve   in   accordance   with   local   codes   and   ensure   that   it   operates   correctly   and   that   air   is   
purged   from   the   valve   prior   to   installing   the   water   heater.   When   connecting   to   Flex   or   High   
Temperature   CPVC   pipe,   we   recommend   that   a   T&P   valve   be   used   for   added   safety.   

Please   note:   Installations   in   the   Commonwealth   of   Massachusetts   and   State   of   Kentucky   require   a   
pressure   relief   valve.   Please   check   your   local   installation   codes   for   any   special   requirements.   

   

3.

  

The   maximum   operating   water   pressure   is   150   PSI.   If   the   water   pressure   is   higher,   a   pressure   reducing   
valve   must   be   installed   on   the   main   incoming   water   supply   line   prior   to   installing   the   electric   tankless   
water   heater.   
   

4.

  

Flexible   water   heater   hoses   are   recommended   to   be   used   with   your   water   heater   as   part   of   the   
installation.   When   connecting   the   inlet   water   pipe   to   the   unit,   make   sure   to   use   a   wrench   to   hold   the   
unit’s   connection,   and   another   wrench   to   tighten,   so   that   the   flow   sensor   on   the   unit   will   not   be   
loosened   or   damaged.   Serious   internal   damage   to   the   water   heater   can   occur   if   the   inlet   or   outlet   
connections   are   over   tightened   or   if   solder   connections   were   made.   
   

5.

  

We   recommend   that   a   manual   shut-­‐off   valve   (ball   valve)   is   installed   on   the   inlet   and   outlet   of   the   water   
heater   so   that   there   is   a   convenient   shut-­‐off   point   available   in   the   event   that   future   maintenance   or   
servicing   is   required.   It   is   extremely   important   to   flush   the   lines   to   eliminate   all   plumbing   paste   or   
residue   in   the   lines   caused   by   any   welding   or   soldering   before   connecting   pipes   to   the   water   heater.      
   

We   recommend   that   all   the   water   pipes   or   hoses   within   3   feet   of   the   inlet   and   outlet   connections   be   rated   for   
high   temperature   applications   with   a   150°F   minimum.      

   

   

Содержание HA008240

Страница 1: ...unit directly at the circuit breaker box SERIOUS BODILY INJURY OR DEATH COULD OCCUR IF YOU IGNORE THIS WARNING THIS PRODUCT SHOULD BE INSTALLED BY A QUALIFIED ELECTRICIAN AND A QUALIFIED PLUMBER IN ACCORDANCE WITH ALL NATIONAL STATE PROVINCIAL AND LOCAL ELECTRICAL PLUMBING CODES PLEASE READ THESE INSTRUCTIONS THOROUGHLY AND COMPLETELY PRIOR TO INSTALLATION USE FAILURE TO DO SO COULD CAUSE PROPERTY...

Страница 2: ...g valve complying with the Standard for Temperature Actuated Mixing Valves for Hot Water Distribution Systems ASSE 1017 be installed The chart shown above may be used as a guide in determining the proper water temperature for your home DANGER Households with small children disabled or elderly persons may require a 120 F or lower thermostat setting to prevent contact with HOT water The temperature ...

Страница 3: ...s at any time please contact us directly at Eemax Inc 400 Captain Neville Drive Waterbury CT 06705 Toll Free 1 800 543 6163 or 203 267 7890 Fax 203 267 7975 info eemaxinc com CONTENTS 1 BEFORE INSTALLATION 2 SELECTING A LOCATION TO INSTALL 3 MOUNTING YOUR WATER HEATER 4 PLUMBING INSTALLATION 5 ELECTRICAL INSTALLATION 6 SIZING GUIDE 7 GENERAL OPERATING INSTRUCTIONS 8 MAINTENANCE 9 TROUBLE SHOOTING ...

Страница 4: ...cal boxes or junctions If you plan to install your water heater on a second floor or in a heated attic space make sure to follow all code requirements for such installations as required for your area We recommend that you install a drip pan connected to a safe drain below the water heater to avoid property damage in the unlikely event of a leak Alternatively you can install an active water leak de...

Страница 5: ...s NOT require that a pressure relief valve be used However a T P valve may be required to meet installation codes in your area If one is required install the pressure relief valve in accordance with local codes and ensure that it operates correctly and that air is purged from the valve prior to installing the water heater When connecting to Flex or High Temperature CPVC pipe we recommend that a T ...

Страница 6: ...nd see wiring diagram Model HA036240 requires 4 sets of wires and ground see wiring diagram Please see electrical specifications by model and wiring diagram on the next page for additional electrical information Each set of wires must be connected to its own individual double pole breaker Installation Instructions STEP 1 Take each wire pair and connect them to one breaker see wiring diagram Make s...

Страница 7: ...50 AMPS REQUIRED BREAKERS 1 x 40 AMP 1 x 50 AMP 1 X 60 AMP 2 X 40 AMP 3 x 40 AMP 3 X 40 AMP 4 X 40 AMP REQUIRED WIRE GAUGE 1 x 8 AWG 1 x 6 AWG 1 x 6 AWG 2 X 8 AWG 3 x 8 AWG 3 X 8 AWG 4 X 8 AWG Wiring Diagram Circuit Breaker 1 L1 L1 Circuit Breaker 2 L2 L2 Circuit Breaker 3 L3 L3 Circuit Breaker 4 L4 L4 BLACK RED BLACK RED BLACK RED BLACK RED HA008240 HA011240 HA013240 require 1 set of breaker and ...

Страница 8: ...ter and limit the maximum volume coming out of your unit to a specified flow rate to prevent the exit temperature from becoming too cool To learn more about flow regulators or find out how to purchase one for your tankless water heater visit us online at Eemax com or contact us at 1 800 543 6163 Steps for Choosing a Flow Regulator 1 Find your model in the chart on the left 2 Choose the column with...

Страница 9: ...er leak we recommend the following maintenance Inspect the connections on the inlet and outlet of the water heater at least on an annual basis for any signs of damage or failure Any signs of damage cracks leakage or weakness should be addressed Take care not to over tighten the connections Serious internal damage to your water heater can occur if you over tighten the water heater connections at th...

Страница 10: ...hat the wiring is incorrect Voltage less than 240 volts The heating elements on your water heater are design for 240 volts When used with a lower voltage they produce less heating power You may need to upgrade to a larger model Mixing too much cold water You do not need to mix as much cold water with your tankless water heater compared to when you use a conventional water heater You may also have ...

Страница 11: ...ving the cover to change the temperature set point exposes electrical shock and burn hazards which can cause INJURY or DEATH Adjustment should only be done by a licensed plumber or electrician HA008240 HA011240 HA013240 HA018240 HA024240 HA027240 HA036240 1 Hot Water Outlet 5 Adjustment Knob Temperature Control 9 Electrical Strain Relief 2 Cold Water Inlet 6 Wire Connection 10 Mounting Bracket 1 3...

Страница 12: ... USA AND CANADA Eemax Inc 400 Captain Neville Drive Waterbury CT 06705 Toll Free 1 800 543 6163 or 203 267 7890 Fax 203 267 7975 info eemaxinc com ...

Отзывы: