background image

 

2-

 

SELECTING A LOCATION TO INSTALL 

This product is designed to be installed indoors only. You may be able to install your unit in an outdoor 
location as long as it is mounted in a suitable enclosure that protects it from rain, splashed water, direct 
sunlight, debris, and insects.  

DO NOT install this product in a location where it may be subject to freezing temperatures. If the water 
inside your tankless water heater freezes, it can cause severe and  permanent damage that is not covered 
under your warranty. 

DO NOT locate the water heater in a location that is difficult to access.  

Make sure that the water heater and hot water outlet pipe are out of the reach of children so they cannot 
tamper with the temperature controls or injure themselves by touching the hot water outlet pipe.  The outlet 
water pipe can get very hot. 

This product does NOT require venting. 

Avoid installing your tankless water heater in a location prone to excessive humidity, moisture, or dust, or in an 
area where it may be splashed with water or other liquids. DO NOT install under water pipes or air conditioning lines 
that might leak or condense moisture that could then drip onto the heater. DO NOT install above electrical 
boxes or junctions. 

If you plan to install your water heater on a second floor or in a heated attic space, make sure that you follow all 
code requirements for such installations as required for your area. We recommend that you install a drip pan 
(connected to a safe drain) below the water heater to avoid property damage in the unlikely event of a leak. 
Alternatively, you can install an active water leak detector and shutoff valve designed to turn off your water 
supply in the event that a leak is ever detected . 

 

 

3-

 

MOUNTING YOUR WATER HEATER 

Your tankless water heater should be secured to the mounting surface with 4 screws (minimum 1 inch long) 
using the built-in mounting brackets on each side of the heater. Make sure that the mounting surface is solid and 
secure, and ensure that the unit is level prior to securing the screws. For ease of installation and servicing, we 
recommend that this product be installed in an upright position with the inlet and outlet water connections at 
the bottom of the unit for the 18, 24, 27, and 36 kW models, and with the inlet and outlet water connections on the 
left and right sides of the unit for the 8, 11, and 13 kW models.  

Recommended Clearances:

               12 inches above and below the heater 

6 inches in front of and to the sides of the heater

 

CAUTION: Combustible materials should be kept at least 24 inches away from your water heater and the hot 
water outlet pipe.

Содержание EEM24008

Страница 1: ...ly at the breaker box SERIOUS BODILY INJURY OR DEATH COULD OCCUR IF YOU IGNORE THIS WARNING THIS PRODUCT SHOULD BE INSTALLED BY A QUALIFIED ELECTRICIAN OR PLUMBER IN ACCORDANCE WITH ALL NATIONAL STATE PROVINCIAL AND LOCAL ELECTRICAL PLUMBING CODES PLEASE READ THESE INSTRUCTIONS THOROUGHLY AND COMPLETELY PRIOR TO INSTALLATION USE FAILURE TO DO SO COULD CAUSE PROPERTY DAMAGE SERIOUS INJURY OR DEATH ...

Страница 2: ......

Страница 3: ...ve any questions please contact us directly at EemaxInc 400CaptainNevilleDrive Waterbury CT06705 Toll Free 1 800 543 6163 or 203 267 7890 Fax 203 267 7975 info eemaxinc com CONTENTS 1 BEFORE INSTALLATION 2 SELECTING A LOCATION TO INSTALL 3 MOUNTING YOUR WATER HEATER 4 PLUMBING INSTALLATION 5 ELECTRICAL INSTALLATION 6 SIZING GUIDE 7 GENERAL OPERATING INSTRUCTIONS 8 MAINTENANCE 9 TROUBLE SHOOTING GU...

Страница 4: ...electrical boxes or junctions If you plan to install your water heater on a second floor or in a heated attic space make sure that you follow all code requirements for such installations as required for your area We recommend that you install a drip pan connected to a safe drain below the water heater to avoid property damage in the unlikely event of a leak Alternatively you can install an active ...

Страница 5: ...ons UL Standard 499 does NOT require that a pressure relief valve be used However a T P valve may be required to meet installation codes in your area If one is required install the pressure relief valve in accordance with local codes and ensure that it operates correctly and that air is purged from the valve prior to installing the water heater When connecting to Flex or High Temperature CPVC pipe...

Страница 6: ...odelEEM24024and EEM24027 require 3 sets of wires and ground seewiringdiagram ModelEEM24036 requires4 sets of wires and ground seewiringdiagram Pleaseseerequiredwiregaugeonthenext page Eachsetof wiresmust beconnectedtoitsownindividualdoublepolebreaker InstallationInstructions STEP1 Takeeachwirepairandconnectthemtoonebreaker seewiringdiagram Makesurethateachbreakeris connectedwithoneblackwireandone ...

Страница 7: ...REQUIRED BREAKERS 1 x 40 AMP 1 x 50 AMP 1 X 60 AMP 2 X 40 AMP 3 x 40 AMP 3 X 40 AMP 4 X 40 AMP REQUIRED WIRE GAUGE 1 x 8 AWG 1 X 6 AWG 1 X 6 AWG 2 X 8 AWG 3 x 8 AWG 3 X 8 AWG 4 X 8 AWG Circuit Breaker 1 L1 L1 EEM24018 requires 2 sets of breakers and wires EEM24024 EEM24027 require 3 sets of breakers and wires EEM24036 requires 4 sets of breakers and wires EEM24008 EEM24011 EEM24013 require 1 set o...

Страница 8: ...t of your unit to a specified flow rate to prevent theexit temperature from becoming too cool To learn moreabout flow restrictors or find out how to purchase one for your tankless water heater visit us online at Eemax com or contact us at 1 800 543 6163 Steps for Choosing a Flow Restrictor 1 Find your modelin the chart on the left 2 Choose the column with the inlet water temperature closestto your...

Страница 9: ...reduce the risk of a water leak we recommend the following maintenance You should inspect the connections on the inlet and outlet of the water heater at least on an annual basis for any signs of damage or failure Any signs of damage cracks leakage or weakness should be address Take care not to over tighten the connections Serious internal damage to your water heater can occur if you over tighten t...

Страница 10: ...ossible that the wiring is incorrect Voltage less than 240 volts The heating elements on your water heater are design for 240 volts When use with a lower voltage they produce less heating power You may need to upgrade to a larger model Mixing too much cold water You do not need to mix as much cold water with your tankless water heater compared to when you use a conventional water heater You may al...

Страница 11: ...the cover to change the temperature set point exposes electrical shock and burn hazards which can cause INJURY or DEATH Adjustment should only be done by a licensed plumber or electrician EEM24008 EEM24011 EEM24013 EEM24018 EEM24024 EEM24027 EEM24036 1 Hot Water Outlet 5 Adjustment Stem Temperature Control 9 Electrical Conduit 2 Cold Water Inlet 6 Wire Connection 10 Mounting Bracket 1 3 Celsius Fa...

Страница 12: ...EemaxInc 400CaptainNevilleDrive Waterbury CT06705 Toll Free 1 800 543 6163 or203 267 7890 Fax 203 267 7975 info eemaxinc com ...

Отзывы: