NEVER USE PIPE DOPE WHEN MAKING PLUMBING
CONNECTIONS TO THIS HEATER. FOLLOW STANDARD
INDUSTRY PRACTICE WITH CAREFUL APPLICATION OF
TEFLON TAPE. DO NOT ALLOW TEFLON TAPE TO GET
INTO THE HEATER.
NEVER SOLDER ANY PIPE CONNECTIONS WHILE
ATTACHED TO THIS HEATER - DAMAGE TO THE HEATER
WILL RESULT. DOING THIS WILL VOID THE WARRANTY.
6
2) PLUMBING HOOK-UP
(continued)
The heater is equipped with NPT brass fittings. Make
sure ONLY NPT fittings are used for connection to this
heater.
Make the cold water inlet connection to the lower RIGHT
fitting and the hot water outlet connection to the lower
LEFT fitting. Reversed connections will cause erratic
operation and premature heater failure.
COLD
WATER
IN
HOT
WATER
OUT
COLD
WATER
IN
HOT
WATER
OUT
PRV Vent is not a code compliant pressure
relief valve. Check local codes to see if a
code compliant PRV is required in your
installation.