PBx0xxxKNXFI01020001.doc
EELECTA
®
KNX PUSH BUTTON
PB40BxxKNX
PB80AxxKNX
PB40CxxKNX
PB80BxxKNX
Product and Applications description
Eelecta
®
pushbutton range of KNX devices is divided in 4 dif-
ferent models based on the number of switch, input and
temperature sensors provided with the device.
Scheme Eelecta® pushbutton range:
Code
Switch
Inputs
Temp. Sensor
PB40BxxKNX
4
-
No
PB40CxxKNX
4
4
Yes
PB80AxKNX
8
-
Yes
PB80BxxKNX
8
4
No
Product has 4 (8) push buttons which can be configured to
manage lights, dimmers, shutters, etc; and 4 inputs (where
present) on the backside to interface free potential contacts
(for example sensors, traditional buttons, etc.)
It has 5 white led in the front side, each led freely configurable
by ets and 2 versions have a temperature sensor included
which can be configured as a room thermostat.
The device is equipped with appropriate communication inter-
face with the bus type TP1 (twisted pair) KNX European stan-
dard, according CEI EN 50090.
Application Program
Application Program
Application Program
Application Program
Downloadable from eelectron website (
www.eelectron.com
)
Maximum number of group addresses:
44
44
44
44
This is the maximum number of different group addresses the
device is able to memorize.
Maximum number of associations:
69
69
69
69
This is the maximum number of associations between com-
munication objects and group addresses the device is able to
memorize.
Technical data
Technical data
Technical data
Technical data
Power Supply:
Via bus EIB/KNX cable
•
Voltage
21..30V DC
•
Current Consumption EIB/KNX
< 10mA
Input
Input
Input
Inputs / buttons
s / buttons
s / buttons
s / buttons
•
Switches : 4 (8 on PB80AxxKNX and PB80BxxKNX)
•
Inputs
: 4 inputs for free potential contacts (on
PB40CxxKNX and PB80BxxKNX)
Note
Note
Note
Note:
:
:
:
4 inputs for free potential contacts must connected
to dry contacts only, in particolar they can be con-
nected to the conventional switch code
PB40AxxCON
PB40AxxCON
PB40AxxCON
PB40AxxCON
•
Maximum Cable Lenght :
≤
10m
•
Voltage Scanning:
3,3 V dc
•
Current Scanning:
≤
1 mA
Output
Output
Output
Output
•
Number: 5 white leds
Control Elements
Control Elements
Control Elements
Control Elements
•
EIB/KNX led and button for physical address programming
Connections
•
EIB/KNX 2 Terminals for connections bus with 0,8mmØ
•
Input
4 connector cable to be wired with 24 AWG
(where present)
Mechanical Data
• Case: polycarbonate and ABS
• Protection class: II in accordance with EN 61140
• Weight: approx. 130 g
Electrical safety
• Degree of pollution (IEC 60664-1): 2
• Degree of protection (EN 60529): IP 20
• Protection class (according to IEC 1140): III
• Overvoltage class (according to IEC 664-1): III
• Bus: safety voltage SELV DC 29 V
• Meets EN 50090 and IEC 664-1: 1992
EMC Requirements
Compliant to EN 50081-1, EN 50082-2 and EN 50090-2.2
Terms of use
• According to EN 50090-2.2
• Ambient temperature during operation: 0 °C +4 5 °C
• Storage temperature: - 20 °C + 55 °C
• Relative humidity: max 90% (not condensing)
Certification
Certification
Certification
Certification
EIB/KNX certificate
CE Mark
According to EMC guideline and low voltage directive
Indicators Position and Control Elements
Indicators Position and Control Elements
Indicators Position and Control Elements
Indicators Position and Control Elements
Switch and led position for
PB80AxxKNX and PB80BxxKNX
Switch and led position for
PB40BxxKNX and PB40CxxKNX
Input position for
PB40CxxKNX and PB80BxxKNX
Inputs:
1.
Input N° 4
2.
Common
3.
Input N° 3
4.
Common
5.
Common
6.
Input N° 2
7.
Common
8.
Input N° 1
Installation Instructions
The device may be used for permanent indoor installations
in dry locations within wall box mounts.
WARNING
•
The device must not be connected to 230V cables
•
The prevailing safety rules must be heeded.
•
The device must be mounted and commissioned by an
authorised installer.
•
The device must not be opened. Any faulty devices
should be returned to manufacturer.
•
For planning and construction of electric installations, the
relevant guidelines, regulations and standards of the re-
spective country are to be considered.
Mounting and Wiring hints
General Description
The device configuration is done by pressing the program-
ming push button located in the back side of the housing.
Please take care during installation to leave connection
wires long enough in order to remove the device easily from
the wall box for commissioning.
Connecting bus cables
•
Connect each single KNX/EIB bus core inside the termi-
nal block observing bus polarity .
•
Slip the bus connection block into the guide slot placed
on the back side of this device and press the block down
to the stop.
For further information please visit
www.eelectron.com