Page 24
A746‐03‐885A ‐ Maintenance
Cleaning and inspecting the pump heads
Use open‐ended wrench to remove fitting at the pump head and remove together with
connecting hose.
Note:
Do not remove bearing flange (1).
Figure 15
Remove the fitting at the pump head
Remove two screws at the handle and remove together with handle.
Figure 16
Remove the handle
Use hex key to remove six socket head screws from pump head and remove upper housing
(housing cover and head cover).
WARNING:
Never remove parts by using a spiky or sharp‐edged tool (e. g. screw driver), we
recommend to use a rubber mallet or compressed air (to be blown carefully into port).
1.
Bearing flange
Содержание XDD1 115 V AC