![Edwards XDD 1 115/230 V Скачать руководство пользователя страница 15](http://html.mh-extra.com/html/edwards/xdd-1-115-230-v/xdd-1-115-230-v_instruction-manual_2366172015.webp)
© Edwards Limited 2010. All rights reserved.
Page 11
Edwards and the Edwards logo are trademarks of Edwards Limited.
Installation
A746-02-885 Issue A
3
Installation
Note:
A suitably trained or qualified technician must carry out the following procedures.
3.1
Electrical connection
3.1.1
XDD1 dual-voltage motor
CAUTION
Ensure that the motor is correctly configured for your electrical supply. If you operate the pump when the motor
is not correctly configured for the electrical supply, you will damage the motor.
CAUTION
Do not change the voltage selector switch while the pump is connected to the mains supply.
Figure 5 - Adjust the supply voltage
1. Selecting 115 covers a voltage supply range of 100 V to 120 V.
2. Selecting 230 covers a voltage supply range of 200 V to 240 V.
Ensure that the voltage shown on the voltage selector switch (
, item 1) corresponds with your electrical
supply voltage. If it does not, you must change the configuration of the pump motor using the voltage selector switch
to match your supply voltage. Use a screw driver to adjust the selector switch to the correct voltage.
WARNING
Ensure that the electrical installation of the XDD1 mains pump conforms with your local and
national safety requirements. It must be connected to a suitably fused and protected electrical
supply and suitable earth point. For electrical data refer to
1. Voltage selector switch