Table 16
Flashing error codes
Error flash
position
Error flash
sequence
Comment
Actions
0
ssssss
Overload timeout.
Check whether the pump is not
running under constant high
pressure or the inlet or outlet is not
blocked.
1
Lsssss
Controller software
error.
Cycle the power to the pump and
see whether the error code appears
again. If it does,contact us or the
supplier.
2
sLssss
Controller failed
internal configuration
and calibration
operation.
Cycle the power to the pump and
see whether the error code appears
again. If it does, contact us or the
supplier.
3
ssLsss
Acceleration timeout.
Check whether the pump is not
running under constant high
pressure or the inlet or outlet is not
blocked.
4
sssLss
Over
‑
current trip
activated, or other
hardware fault.
Cycle the power to the pump and
see whether the error code appears
again. If it does, contact us or the
supplier.
5
ssssLs
Self test fault.
Cycle the power to the pump and
see whether the error code appears
again. If it does, contact us or the
supplier.
6
sssssL
Serial Control Mode
Interlock.
Re
‑
activate serial enable and send a
serial command to clear the error
code.
Page 46
A73501880_G - Fault finding