Figure 14 Noisy pump flow chart
7.5 The pump surface temperature is high
▪
The ambient temperature is too high.
▪
The cooling fan is not running.
▪
The process gas is too hot or the maximum continuous operating pressure has
been exceeded.
7.6 Alarm indicator codes
Whenever a fail condition becomes active the red alarm indicator shows a flashing
sequence. If the error light is on continuously this indicates a problem has been found
with the embedded software. In this case, try cycling the power. If cycling the power
does not clear the indication, a software download may be required. In this situation,
contact us or the supplier. If the alarm indicator is flashing, identify the error flash code
and consult
Table: Flashing error codes on page 46
There is a sufficient off period between each subsequent cycle repetition to clearly mark
the start of a new flash sequence. The duration of a long flash (L) is equal to 3 times the
duration of a short flash (0.5 s).
Page 45
A73501880_G - Fault finding