To set a vent option on auxiliary output 1, send the command that follows (character 'd'
refers to the option number shown in
):
Command
!
S
8
5
3
sp
d
cr
The reply is as follows:
Reply
*
S
8
5
3
sp
r
cr
The venting option is now stored in the memory of the pump.
To check what venting option is set, send a query that follows:
Command
?
S
8
5
3
cr
The reply is as follows:
Reply
=
S
8
5
3
sp
d
cr
To set the valve type on auxiliary output 1, send the command that follows (character 'd'
refers to the option number shown in
Reply
!
S
8
7
7
sp
d
cr
The reply is as follows:
Reply
*
S
8
7
7
sp
d
cr
The valve type is now stored in the memory of the pump, but a power cycle is necessary
before the auxiliary 1 output circuit adjusts to the stored request.
To check what venting option is set, send a query as follows:
Reply
?
S
8
7
7
cr
The reply is as follows:
Reply
=
S
8
7
7
sp
d
cr
5.1.6 Standby speed setting
You can operate the pump at a standby speed rather than full rotational speed. The
standby speed is a user-configurable option and can be set to the value between 55%
and 100% full rotational speed. When the pump is shipped, it is configured with a
standby speed of 70% full rotational speed.
To change the standby speed setting, use one of the methods that follows:
▪
Use the STDBY+ and STDBY- push buttons (given on the motor controller). Each
push of the button adjusts the speed by 15 Hz (1%). Refer to
.
▪
Use a serial command
To change the standby speed setting using a serial command, send the command that
follows (characters 'd' shows the value as a percentage of full rotational speed):
Command
!
S
8
5
7
sp
d
d
d
cr
The reply is as follows:
Reply
*
S
8
5
7
sp
r
cr
07/2021 - ©Edwards Limited
Page 65
B8G000880_E
B8G000880_E - Configuration