© Edwards Limited 2015. All rights reserved.
Page 41
Edwards and the Edwards logo are trademarks of Edwards Limited.
Transportation, storage and disposal
A540-55-880 Issue D
6
Transportation, storage and disposal
6.1
Transportation
Follow the procedure laid out in
and then read form HS1 and fill out form HS2, which can be found at the
back of this manual.
6.2
Storage
Drain the cooling water from the system if it will transported or stored in conditions where the cooling water could
freeze (refer to
). If the cooling water is not drained from the system, it may freeze in the system and
damage the pump(s) and/or the cooling water pipelines.
Store the system as follows:
1. Follow the procedure set out in
2. Store the system in clean dry conditions until required.
3. When required for use, prepare and install the system as described in
of this manual.
6.3
Disposal
Edwards products are supported by a world-wide network of Edwards Service Centres. Each Service Centre offers a
wide range of options including disposal. Refer to
for more information.
Pump system materials suitable for recycling include cast iron, steel, PTFE, stainless steel, brass, aluminium, zinc
alloy, nickel, mild steel, ABS, polyamide.
Take particular care with the following:
Fluoroelastomers which may have decomposed as the result of being subjected to high temperatures.
Components which have been contaminated with dangerous process substances.
Lithium battery.
WARNING
Do not drain the oil from the pump(s) whether dangerous substances have been pumped or not.
Fit blanking plates to seal all vacuum inlet and outlet ports (to prevent possible oil leakage). Ensure
that the system is correctly labelled. If in doubt, contact Edwards.
WARNING
Dispose of the system and any components safely and in accordance with all local and national
safety and environmental requirements.
This equipment may contain a lithium manganese dioxide battery which, under California law,
requires notification for the presence of perchlorate: Perchlorate Material - special handling may