© Edwards Limited 2018. All rights reserved.
Page 29
Edwards and the Edwards logo are trademarks of Edwards Limited.
Installation
B722-40-880 Issue H
Table 15 - Command abbreviations
Abbreviation
Meaning
cr
carriage return character
chars
characters
d
decimal ASCII character
Note:
Fields showing multiple d characters are to indicate typical length. All
data fields have a maximum of 5 decimal characters (prefixed by a minus
number for negative numbers).
h
hexadecimal ASCII character
r
Returned error code - refer to
sp
space character
string
may have several ASCII characters
X
Multi-drop decimal ASCII character
Note:
Fields showing multiple X characters are to indicate maximum length and
not fixed length.
Table 16 - Error codes
Returned error code
Meaning
0
No error
1
Invalid command for object ID
2
Invalid Query/Command
3
Missing parameter
4
Parameter out of range
5
Invalid command in current state - e.g. serial command to start/stop when in
parallel control mode