A462-26-880 Issue F
Page 8
© Edwards Limited 2008. All rights reserved.
Edwards and the Edwards logo are trademarks of Edwards Limited.
Installation
3.2.2
Install the EMF filter on other pumps
You must install the EMF filter vertically with the direction of exhaust flow as indicated by the arrow on the lower
part of the body. Use the following procedure and refer to
Figure 3
:
1. Clean the area around the pump outlet connection.
2. On E1M and E2M pumps only, unscrew and remove the outlet connection from the pump, fit the O-ring seal (5) to
the adaptor (4) and screw the adaptor into the pump outlet; do not overtighten the adaptor or you will damage
the O-ring seal.
3. Ensure that the sealing surfaces of the filter assembly and pump outlet (or adaptor) are clean, fit the
centring-ring (2) to the pump outlet (or adaptor, on E1M and E2M pumps), then position the filter assembly
flange on the O-ring. If necessary, rotate the filter so that the oil-level sight panel is visible and so that you can
access the drain plug to drain the filter.
4. Fit the clamp (3) and tighten (hand tight only).
5. If required, use a further centring-ring and O-ring and clamp (not supplied) to fit an exhaust pipeline to the
outlet of the filter.
Figure 3 - Fit the filter to the pump
1. Filter
2. Centring-ring and O-ring
3. Clamp
4. Adaptor
5. O-ring
6. Pump